Literature DB >> 23796954

Optimization of adenovirus 40 and 41 recovery from tap water using small disk filters.

Brian R McMinn1.   

Abstract

Currently, the U.S. Environmental Protection Agency's Information Collection Rule (ICR) for the primary concentration of viruses from drinking and surface waters uses the 1MDS filter, but a more cost effective option, the NanoCeram® filter, has been shown to recover comparable levels of enterovirus and norovirus from both matrices. In order to achieve the highest viral recoveries, filtration methods require the identification of optimal concentration conditions that are unique for each virus type. This study evaluated the effectiveness of 1MDS and NanoCeram filters in recovering adenovirus (AdV) 40 and 41 from tap water, and optimized two secondary concentration procedures the celite and organic flocculation method. Adjustments in pH were made to both virus elution solutions and sample matrices to determine which resulted in higher virus recovery. Samples were analyzed by quantitative PCR (qPCR) and Most Probable Number (MPN) techniques and AdV recoveries were determined by comparing levels of virus in sample concentrates to that in the initial input. The recovery of adenovirus was highest for samples in unconditioned tap water (pH 8) using the 1MDS filter and celite for secondary concentration. Elution buffer containing 0.1% sodium polyphosphate at pH 10.0 was determined to be most effective overall for both AdV types. Under these conditions, the average recovery for AdV40 and 41 was 49% and 60%, respectively. By optimizing secondary elution steps, AdV recovery from tap water could be improved at least two-fold compared to the currently used methodology. Identification of the optimal concentration conditions for human AdV (HAdV) is important for timely and sensitive detection of these viruses from both surface and drinking waters. Published by Elsevier B.V.

Entities:  

Keywords:  1MDS; Adenovirus 40 and 41; Celite concentration; NanoCeram(®); Organic flocculation

Mesh:

Substances:

Year:  2013        PMID: 23796954     DOI: 10.1016/j.jviromet.2013.06.021

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  A small volume procedure for viral concentration from water.

Authors:  Brian R McMinn; Asja Korajkic
Journal:  J Vis Exp       Date:  2015-02-03       Impact factor: 1.355

2.  Effectiveness of two wastewater disinfection strategies for the removal of fecal indicator bacteria, bacteriophage, and enteric viral pathogens concentrated using dead-end hollow fiber ultrafiltration (D-HFUF).

Authors:  Asja Korajkic; Julie Kelleher; Orin C Shanks; Michael P Herrmann; Brian R McMinn
Journal:  Sci Total Environ       Date:  2022-03-28       Impact factor: 10.753

3.  Elution Is a Critical Step for Recovering Human Adenovirus 40 from Tap Water and Surface Water by Cross-Flow Ultrafiltration.

Authors:  Hang Shi; Irene Xagoraraki; Kristin N Parent; Merlin L Bruening; Volodymyr V Tarabara
Journal:  Appl Environ Microbiol       Date:  2016-07-29       Impact factor: 4.792

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.