Literature DB >> 23796384

Addressing glenoid bone deficiency and asymmetric posterior erosion in shoulder arthroplasty.

Jason E Hsu1, Eric T Ricchetti, G Russell Huffman, Joseph P Iannotti, David L Glaser.   

Abstract

Glenoid bone deficiency and eccentric posterior wear are difficult problems faced by shoulder arthroplasty surgeons. Numerous options and techniques exist for addressing these issues. Hemiarthroplasty with concentric glenoid reaming may be a viable alternative in motivated patients in whom glenoid component failure is a concern. Total shoulder arthroplasty has been shown to provide durable pain relief and excellent function in patients, and numerous methods and techniques can assist in addressing bone loss and eccentric wear. However, the ideal amount of version correction in cases of severe retroversion has not yet been established. Asymmetric reaming is a commonly used technique to address glenoid version, but correction of severe retroversion may compromise bone stock and component fixation. Bone grafting is a technically demanding alternative for uncontained defects and has mixed clinical results. Specialized glenoid implants with posterior augmentation have been created to assist the surgeon in correcting glenoid version without compromising bone stock, but clinical data on these implants are still pending. Custom implants or instruments based on each patient's unique glenoid anatomy may hold promise. In elderly, sedentary patients in whom bone stock and soft-tissue balance are concerns, reverse total shoulder arthroplasty may be less technically demanding while still providing satisfactory pain relief and functional improvements.
Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  Glenoid; Review article; asymmetric reaming; bone grafting; glenoid anatomy; glenoid version; posterior wear; retroversion; shoulder arthroplasty

Mesh:

Year:  2013        PMID: 23796384     DOI: 10.1016/j.jse.2013.04.014

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  21 in total

1.  The arthritic glenoid: anatomy and arthroplasty designs.

Authors:  Nikolas K Knowles; Louis M Ferreira; George S Athwal
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Surgical management of the biconcave (B2) glenoid.

Authors:  Kenneth W Donohue; Eric T Ricchetti; Joseph P Iannotti
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

3.  Risk of Perforation Is High During Corrective Reaming of Retroverted Glenoids: A Computer Simulation Study.

Authors:  Alexander W Aleem; Nathan D Orvets; Brendan C Patterson; Aaron M Chamberlain; Jay D Keener
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

4.  Short term results of reverse total shoulder arthroplasty.

Authors:  Aditya K Agrawal; Carlos Wigderowitz; Bruno Ribeiro; Amar Malhas; Abhishek Vaish; Rami Abboud
Journal:  J Clin Orthop Trauma       Date:  2019-08-12

5.  Version Correction via Eccentric Reaming Compromises Remaining Bone Quality in B2 Glenoids: A Computational Study.

Authors:  Xiang Chen; Akhil S Reddy; Andreas Kontaxis; Daniel S Choi; Timothy Wright; David M Dines; Russell F Warren; Julien Berhouet; Lawrence V Gulotta
Journal:  Clin Orthop Relat Res       Date:  2017-09-25       Impact factor: 4.176

6.  Does Postoperative Glenoid Retroversion Affect the 2-Year Clinical and Radiographic Outcomes for Total Shoulder Arthroplasty?

Authors:  Benjamin C Service; Jason E Hsu; Jeremy S Somerson; Stacy M Russ; Frederick A Matsen
Journal:  Clin Orthop Relat Res       Date:  2017-07-05       Impact factor: 4.176

7.  Can the ream and run procedure improve glenohumeral relationships and function for shoulders with the arthritic triad?

Authors:  Frederick A Matsen; Winston J Warme; Sarah E Jackins
Journal:  Clin Orthop Relat Res       Date:  2014-12-09       Impact factor: 4.176

8.  Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study.

Authors:  Abdul Hadi Abdul Wahab; Mohammed Rafiq Abdul Kadir; Muhammad Noor Harun; Tunku Kamarul; Ardiyansyah Syahrom
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

9.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

10.  Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study.

Authors:  Jia-Wei Kevin Ko; Usman Ali Syed; Jonathan D Barlow; Scott Paxton; Bryan J Loeffler; Ocean Thakar; Grant Jamgochian; Joseph A Abboud; Charles L Getz; Gerald R Williams
Journal:  Arch Bone Jt Surg       Date:  2019-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.