Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy: results of the European Heart Rhythm Association survey.

Alessandro Proclemer1, Thorsten Lewalter, Maria Grazia Bongiorni, Jesper Hastrup Svendsen, Jesper Hastrup Nielsen, Laurent Pison, Carina Blomström Lundqvist.   

Abstract

The purpose of this EHRA survey was to examine the current clinical practice of screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy with a focus on selection of candidates for implantable cardioverter-defibrillator (ICD) therapy, timing of ICD implantation, and use of non-invasive and invasive diagnostic tests across Europe. A systematic screening programme for sudden cardiac death existed in 19 out of 31 centres (61.3%). Implantation of ICDs according to the inclusion criteria of MADIT-II and SCD-HeFT trials was reported in 30 and 29% of centres, respectively, followed by MADIT-CRT (18%), COMPANION (16%), and combined MADIT and MUSTT (7%) indications. In patients with severe renal impairment, ICD implantation for primary prevention of sudden death was always avoided in 8 centres (33.3%), was not used only if creatinine level was >2.5 mg/dL in 10 centres (32.2%), and in patients with permanent dialysis in 8 centres (33.3%). Signal-averaged electrocardiography and heart rate variability were never considered as risk stratification tools in 23 centres (74.2%). Implantation of a loop recorder was performed in patients with borderline indications for ICD therapy in 6 centres (19.4%), for research purposes in 5 (16.1%), and was never performed in 20 (64.5%) centres. In conclusion, the majority of participating European centres have a screening programme for sudden cardiac death and the selection of candidates for ICD therapy was mainly based on the clinical risk stratification and not on non-invasive and invasive diagnostic tests or implantable loop recorder use.

Entities:  

Keywords:  EHRA survey; EP wire; Implantable cardioverter-defibrillator; Ischaemic cardiomyopathy; Non-ischaemic cardiomyopathy; Risk stratification; Screening; Sudden cardiac death

Mesh:

Year:  2013        PMID: 23794672     DOI: 10.1093/europace/eut187

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

Review 1.  [ICD therapy in the primary prevention of sudden cardiac death: Risk stratification and patient selection].

Authors:  J Neuzner; R Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-06-04

2.  Value of implantable loop recorders in patients with structural or electrical heart disease.

Authors:  Rafi Sakhi; Dominic A M J Theuns; Rohit E Bhagwandien; Michelle Michels; Arend F L Schinkel; Tamas Szili-Torok; F Zijlstra; Jolien W Roos-Hesselink; Sing-Chien Yap
Journal:  J Interv Card Electrophysiol       Date:  2018-03-13       Impact factor: 1.900

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.