PURPOSE: To present a new acquisition and analysis protocol for reliable and reproducible segmentation of the entire intraorbital optic nerve (ION) mean cross-sectional area by means of magnetic resonance imaging (MRI) at 3 tesla (T). METHODS: Eight healthy volunteers (mean age 31, five were male) gave written informed consent and both of their IONs were imaged individually using a coronal-oblique T2-weighted fast multidynamic image acquisition scheme; the proposed acquisition scheme has its rationale in combining separately acquired volumes and registering them to account for motion-related artifacts commonly associated with longer acquisitions. Mean cross-sectional area of each ION was measured using a semiautomated image analysis protocol that was based on an active surface model previously described and used for spinal cord imaging. Reproducibility was assessed for repeated scans (scan-rescan) and repeated image analysis performance (intraobserver). RESULTS: Mean and SD values of the left ION cross-sectional area for the eight healthy volunteers were 5.0 (±0.7) mm² and for the right ION were 5.3 (±0.8) mm². Mean scan-rescan coefficient of variation (COV) for the left ION was 4.3% and for the right was 4.4%. Mean intraobserver COV for the left ION was 2.1% and for the right was 1.8%. CONCLUSIONS: This study presents a new MRI acquisition and analysis protocol for reliable and reproducible in vivo measurement of the entire ION mean cross-sectional area as demonstrated in a pilot study of healthy subjects. The protocol presented here can be used in future studies of the ION in disease state.
PURPOSE: To present a new acquisition and analysis protocol for reliable and reproducible segmentation of the entire intraorbital optic nerve (ION) mean cross-sectional area by means of magnetic resonance imaging (MRI) at 3 tesla (T). METHODS: Eight healthy volunteers (mean age 31, five were male) gave written informed consent and both of their IONs were imaged individually using a coronal-oblique T2-weighted fast multidynamic image acquisition scheme; the proposed acquisition scheme has its rationale in combining separately acquired volumes and registering them to account for motion-related artifacts commonly associated with longer acquisitions. Mean cross-sectional area of each ION was measured using a semiautomated image analysis protocol that was based on an active surface model previously described and used for spinal cord imaging. Reproducibility was assessed for repeated scans (scan-rescan) and repeated image analysis performance (intraobserver). RESULTS: Mean and SD values of the left ION cross-sectional area for the eight healthy volunteers were 5.0 (±0.7) mm² and for the right ION were 5.3 (±0.8) mm². Mean scan-rescan coefficient of variation (COV) for the left ION was 4.3% and for the right was 4.4%. Mean intraobserver COV for the left ION was 2.1% and for the right was 1.8%. CONCLUSIONS: This study presents a new MRI acquisition and analysis protocol for reliable and reproducible in vivo measurement of the entire ION mean cross-sectional area as demonstrated in a pilot study of healthy subjects. The protocol presented here can be used in future studies of the ION in disease state.
Authors: Robert L Harrigan; Andrew J Plassard; Frederick W Bryan; Gabriela Caires; Louise A Mawn; Lindsey M Dethrage; Siddharama Pawate; Robert L Galloway; Seth A Smith; Bennett A Landman Journal: Magn Reson Med Date: 2015-03-07 Impact factor: 4.668
Authors: Robert A Avery; Awais Mansoor; Rabia Idrees; Elijah Biggs; Mohammad Ali Alsharid; Roger J Packer; Marius George Linguraru Journal: Neurology Date: 2016-05-11 Impact factor: 9.910
Authors: Robert L Harrigan; Andrew J Plassard; Louise A Mawn; Robert L Galloway; Seth A Smith; Bennett A Landman Journal: Proc SPIE Int Soc Opt Eng Date: 2015-03-20
Authors: Axel Petzold; Mike P Wattjes; Fiona Costello; Jose Flores-Rivera; Clare L Fraser; Kazuo Fujihara; Jacqueline Leavitt; Romain Marignier; Friedemann Paul; Sven Schippling; Christian Sindic; Pablo Villoslada; Brian Weinshenker; Gordon T Plant Journal: Nat Rev Neurol Date: 2014-07-08 Impact factor: 42.937
Authors: Cezary Grochowski; Mark Symms; Kamil Jonak; Paweł Krukow; Tobias Wood; Emil Ljungberg; Joaquim Enseñat; Katarzyna Nowomiejska; Robert Rejdak; Ryszard Maciejewski; Gareth J Barker Journal: J Clin Med Date: 2020-04-13 Impact factor: 4.241