Literature DB >> 23794131

FID modulus: a simple and efficient technique to phase and align MR spectra.

Yann Le Fur1, Patrick J Cozzone.   

Abstract

OBJECT: The post-processing of MR spectroscopic data requires several steps more or less easy to automate, including the phase correction and the chemical shift assignment. First, since the absolute phase is unknown, one of the difficulties the MR spectroscopist has to face is the determination of the correct phase correction. When only a few spectra have to be processed, this is usually performed manually. However, this correction needs to be automated as soon as a large number of spectra is involved, like in the case of phase coherent averaging or when the signals collected with phased array coils have to be combined. A second post-processing requirement is the frequency axis assignment. In standard mono-voxel MR spectroscopy, this can also be easily performed manually, by simply assigning a frequency value to a well-known resonance (e.g. the water or NAA resonance in the case of brain spectroscopy). However, when the correction of a frequency shift is required before averaging a large amount of spectra (due to B 0 spatial inhomogeneities in chemical shift imaging, or resulting from motion for example), this post-processing definitely needs to be performed automatically.
MATERIALS AND METHODS: Zero-order phase and frequency shift of a MR spectrum are linked respectively to zero-order and first-order phase variations in the corresponding free induction decay (FID) signal. One of the simplest ways to remove the phase component of a signal is to calculate the modulus of this signal: this approach is the basis of the correction technique presented here.
RESULTS: We show that selecting the modulus of the FID allows, under certain conditions that are detailed, to automatically phase correct and frequency align the spectra. This correction technique can be for example applied to the summation of signals acquired from combined phased array coils, to phase coherent averaging and to B 0 shift correction.
CONCLUSION: We demonstrate that working on the modulus of the FID signal is a simple and efficient way to both phase correct and frequency align MR spectra automatically. This approach is particularly well suited to brain proton MR spectroscopy.

Entities:  

Mesh:

Year:  2013        PMID: 23794131     DOI: 10.1007/s10334-013-0381-8

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  28 in total

Review 1.  Wavelets and related time-frequency techniques in magnetic resonance spectroscopy.

Authors:  J P Antoine; C Chauvin; A Coron
Journal:  NMR Biomed       Date:  2001-06       Impact factor: 4.044

2.  Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis.

Authors:  A Ebel; B J Soher; A A Maudsley
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

3.  An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes.

Authors:  T Prock; D J Collins; A S K Dzik-Jurasz; M O Leach
Journal:  Phys Med Biol       Date:  2002-01-21       Impact factor: 3.609

4.  Toward quantitative short-echo-time in vivo proton MR spectroscopy without water suppression.

Authors:  Zhengchao Dong; Wolfgang Dreher; Dieter Leibfritz
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

5.  Time-domain combination of MR spectroscopy data acquired using phased-array coils.

Authors:  Mark A Brown
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

6.  In vivo lactate editing with simultaneous detection of choline, creatine, NAA, and lipid singlets at 1.5 T using PRESS excitation with applications to the study of brain and head and neck tumors.

Authors:  J Star-Lack; D Spielman; E Adalsteinsson; J Kurhanewicz; D J Terris; D B Vigneron
Journal:  J Magn Reson       Date:  1998-08       Impact factor: 2.229

7.  In vivo proton spectroscopy in presence of eddy currents.

Authors:  U Klose
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

8.  Improved method for accurate and efficient quantification of MRS data with use of prior knowledge

Authors: 
Journal:  J Magn Reson       Date:  1997-11       Impact factor: 2.229

9.  Estimation of the noise in magnitude MR images.

Authors:  J Sijbers; A J den Dekker; J Van Audekerke; M Verhoye; D Van Dyck
Journal:  Magn Reson Imaging       Date:  1998       Impact factor: 2.546

10.  Subtraction artifacts and frequency (mis-)alignment in J-difference GABA editing.

Authors:  C John Evans; Nicolaas A J Puts; Siân E Robson; Frederic Boy; David J McGonigle; Petroc Sumner; Krish D Singh; Richard A E Edden
Journal:  J Magn Reson Imaging       Date:  2012-11-27       Impact factor: 4.813

View more
  5 in total

1.  Fast water concentration mapping to normalize (1)H MR spectroscopic imaging.

Authors:  Angèle Lecocq; Yann Le Fur; Alexis Amadon; Alexandre Vignaud; Patrick J Cozzone; Maxime Guye; Jean-Philippe Ranjeva
Journal:  MAGMA       Date:  2014-06-08       Impact factor: 2.310

2.  Hemi-spectrum substitution after water signal fitting (HESWAF): an improvement of the modulus post-processing of MR spectra.

Authors:  Yann Le Fur; Patrick J Cozzone
Journal:  MAGMA       Date:  2014-06-03       Impact factor: 2.310

3.  Absolute choline tissue concentration mapping for prostate cancer localization and characterization using 3D 1 H MRSI without water-signal suppression.

Authors:  Nassim Tayari; Alan J Wright; Arend Heerschap
Journal:  Magn Reson Med       Date:  2021-09-23       Impact factor: 3.737

4.  Dissociable roles for the striatal cholinergic system in different flexibility contexts.

Authors:  Brendan Williams; Anastasia Christakou
Journal:  IBRO Neurosci Rep       Date:  2022-04-01

Review 5.  Developments in proton MR spectroscopic imaging of prostate cancer.

Authors:  Angeliki Stamatelatou; Tom W J Scheenen; Arend Heerschap
Journal:  MAGMA       Date:  2022-04-20       Impact factor: 2.533

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.