Literature DB >> 23793511

Localization of coherent sources by simultaneous MEG and EEG beamformer.

Jun Hee Hong1, Minkyu Ahn, Kiwoong Kim, Sung Chan Jun.   

Abstract

Simultaneous magnetoencephalography (MEG) and electroencephalography (EEG) analysis is known generally to yield better localization performance than a single modality only. For simultaneous analysis, MEG and EEG data should be combined to maximize synergistic effects. Recently, beamformer for simultaneous MEG/EEG analysis was proposed to localize both radial and tangential components well, while single modality analyses could not detect them, or had relatively higher location bias. In practice, most interesting brain sources are likely to be activated coherently; however, conventional beamformer may not work properly for such coherent sources. To overcome this difficulty, a linearly constrained minimum variance (LCMV) beamformer may be used with a source suppression strategy. In this work, simultaneous MEG/EEG LCMV beamformer using source suppression was formulated firstly to investigate its capability over various suppression strategies. The localization performance of our proposed approach was examined mainly for coherent sources and compared thoroughly with the conventional simultaneous and single modality approaches, over various suppression strategies. For this purpose, we used numerous simulated data, as well as empirical auditory stimulation data. In addition, some strategic issues of simultaneous MEG/EEG analysis were discussed. Overall, we found that our simultaneous MEG/EEG LCMV beamformer using a source suppression strategy is greatly beneficial in localizing coherent sources.

Entities:  

Mesh:

Year:  2013        PMID: 23793511     DOI: 10.1007/s11517-013-1092-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  29 in total

1.  Combined MEG and EEG source imaging by minimization of mutual information.

Authors:  S Baillet; L Garnero; G Marin; J P Hugonin
Journal:  IEEE Trans Biomed Eng       Date:  1999-05       Impact factor: 4.538

2.  Reconstructing spatio-temporal activities of neural sources using an MEG vector beamformer technique.

Authors:  K Sekihara; S S Nagarajan; D Poeppel; A Marantz; Y Miyashita
Journal:  IEEE Trans Biomed Eng       Date:  2001-07       Impact factor: 4.538

3.  A consensus statement on relative merits of EEG and MEG. European Concerted Action on Biomagnetism, Lyon meeting, November 26 and 27, 1991.

Authors:  F Mauguière
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1992-05

Review 4.  Mapping human brain function with MEG and EEG: methods and validation.

Authors:  F Darvas; D Pantazis; E Kucukaltun-Yildirim; R M Leahy
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

Review 5.  EEG versus MEG localization accuracy: theory and experiment.

Authors:  D Cohen; B N Cuffin
Journal:  Brain Topogr       Date:  1991       Impact factor: 3.020

6.  Application of multi-source minimum variance beamformers for reconstruction of correlated neural activity.

Authors:  Alexander Moiseev; John M Gaspar; Jennifer A Schneider; Anthony T Herdman
Journal:  Neuroimage       Date:  2011-06-16       Impact factor: 6.556

7.  Dynamic imaging of coherent sources: Studying neural interactions in the human brain.

Authors:  J Gross; J Kujala; M Hamalainen; L Timmermann; A Schnitzler; R Salmelin
Journal:  Proc Natl Acad Sci U S A       Date:  2001-01-16       Impact factor: 11.205

8.  Magnetoencephalography: evidence of magnetic fields produced by alpha-rhythm currents.

Authors:  D Cohen
Journal:  Science       Date:  1968-08-23       Impact factor: 47.728

9.  Benefit of simultaneous recording of EEG and MEG in dipole localization.

Authors:  Harumi Yoshinaga; Tomoyuki Nakahori; Yoko Ohtsuka; Eiji Oka; Yoshihiro Kitamura; Hideki Kiriyama; Kazumasa Kinugasa; Keiichi Miyamoto; Toru Hoshida
Journal:  Epilepsia       Date:  2002-08       Impact factor: 5.864

10.  MEG and EEG data fusion: simultaneous localisation of face-evoked responses.

Authors:  Richard N Henson; Elias Mouchlianitis; Karl J Friston
Journal:  Neuroimage       Date:  2009-05-03       Impact factor: 6.556

View more
  5 in total

1.  Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy.

Authors:  Rasheda Arman Chowdhury; Giovanni Pellegrino; Ümit Aydin; Jean-Marc Lina; François Dubeau; Eliane Kobayashi; Christophe Grova
Journal:  Hum Brain Mapp       Date:  2017-11-21       Impact factor: 5.038

2.  MEG-EEG Information Fusion and Electromagnetic Source Imaging: From Theory to Clinical Application in Epilepsy.

Authors:  Rasheda Arman Chowdhury; Younes Zerouali; Tanguy Hedrich; Marcel Heers; Eliane Kobayashi; Jean-Marc Lina; Christophe Grova
Journal:  Brain Topogr       Date:  2015-05-28       Impact factor: 3.020

Review 3.  Functional Neurophysiological Biomarkers of Early-Stage Alzheimer's Disease: A Perspective of Network Hyperexcitability in Disease Progression.

Authors:  Sean Tok; Abdallah Ahnaou; Wilhelmus Drinkenburg
Journal:  J Alzheimers Dis       Date:  2022       Impact factor: 4.160

4.  Gamma band activity associated with BCI performance: simultaneous MEG/EEG study.

Authors:  Minkyu Ahn; Sangtae Ahn; Jun H Hong; Hohyun Cho; Kiwoong Kim; Bong S Kim; Jin W Chang; Sung C Jun
Journal:  Front Hum Neurosci       Date:  2013-12-06       Impact factor: 3.169

5.  Code-modulated visual evoked potentials using fast stimulus presentation and spatiotemporal beamformer decoding.

Authors:  Benjamin Wittevrongel; Elia Van Wolputte; Marc M Van Hulle
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.