Systematical assessment of serum indices does not impair efficiency of clinical chemistry testing: a multicenter study.

Giuseppe Lippi1, Paola Avanzini, Daniele Campioli, Giorgio Da Rin, Mariella Dipalo, Rosalia Aloe, Davide Giavarina, Gian Luca Salvagno.   

Abstract

OBJECTIVES: Despite manufacturers' claim that systematical assessment of serum indices does not impact on testing efficiency, there is widespread perception that this practice may increase the turnaround time (TAT). A multicenter investigation was planned to verify TAT and performance of serum indices on five different clinical chemistry analyzers. DESIGN AND METHODS: Twenty study samples prepared from pooled sera of outpatients, emergency department, intensive care unit and dialyzed patients were divided in aliquots and shipped to 5 different laboratories. According to local instrumentation (Beckman Coulter AU5800, Roche Cobas 6000, Siemens Dimension Vista 1500, Abbott Architect c 16000 and Ortho Vitros 5.1/FS) and reagents, 13 clinical chemistry parameters were assayed on all study samples, with or without contextual assessment of serum indices.
RESULTS: The TAT with assessment of serum indices modestly or even negligibly increased, and varied from -0.2 to +5.0% (i.e., from -3 to +85 s). When using the lowest thresholds for sample acceptability, the agreement of hemolysis index (HI) among different instruments was comprised between 0.62 and 1.00 (all p<0.01), but was higher than 0.80 in only 4/10 cases. The agreement of icteric and lipaemic indices could not be estimated due to the low number of samples exceeding acceptability criteria.
CONCLUSIONS: The results of this study confirm that systematical measurement of serum indices does not impair instrument efficiency. The comparison of HI also suggests that major harmonization may be advisable for this measure among different manufacturers and instrumentations.
Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Hemolysis; Preanalytical variability; Sample quality; Serum indices

Mesh:

Year:  2013        PMID: 23792262     DOI: 10.1016/j.clinbiochem.2013.06.007

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  3 in total

1.  Data on the frequency and causes of icteric interference in clinical chemistry laboratory tests.

Authors:  Anna E Merrill; Sandhya Mainali; Matthew D Krasowski
Journal:  Data Brief       Date:  2021-12-30

2.  Frequency of icteric interference in clinical chemistry laboratory tests and causes of severe icterus.

Authors:  Sandhya Mainali; Anna E Merrill; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2021-10-23

3.  Utility of serum indices in a particular case of serum protein electrophoresis.

Authors:  Massimo Daves; Andrea Piccin; Cristina Vicidomini; Antonia De Luisi; Andrea Mega
Journal:  Biochem Med (Zagreb)       Date:  2022-08-05       Impact factor: 2.515

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.