Literature DB >> 23791781

Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test.

Emer P Doheny1, Cathal Walsh, Timothy Foran, Barry R Greene, Chie Wei Fan, Clodagh Cunningham, Rose Anne Kenny.   

Abstract

The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 with a history of falls, performed four repetitions of the FTSS in their homes. A tri-axial accelerometer was attached to the lateral thigh and used to identify each sit-stand-sit phase and sit-stand and stand-sit transitions. A second tri-axial accelerometer, attached to the sternum, captured torso acceleration. The mean and variation of the root-mean-squared amplitude, jerk and spectral edge frequency of the acceleration during each section of the assessment were examined. The test-retest reliability of each feature was examined using intra-class correlation analysis, ICC(2,k). A model was developed to classify participants according to falls status. Only features with ICC>0.7 were considered during feature selection. Sequential forward feature selection within leave-one-out cross-validation resulted in a model including four reliable accelerometer-derived features, providing 74.4% classification accuracy, 80.0% specificity and 68.7% sensitivity. An alternative model using FTSS time alone resulted in significantly reduced classification performance. Results suggest that the described methodology could provide a robust and accurate falls risk assessment.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Accelerometer; Classifier; Falls risk assessment; Logistic regression; Postural transitions

Mesh:

Year:  2013        PMID: 23791781     DOI: 10.1016/j.gaitpost.2013.05.013

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  31 in total

1.  Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept.

Authors:  Chien-Hung Yeh; Chi-Yao Hung; Yung-Hung Wang; Wei-Tai Hsu; Yi-Chung Chang; Jia-Rong Yeh; Po-Lei Lee; Kun Hu; Jiunn-Horng Kang; Men-Tzung Lo
Journal:  Gait Posture       Date:  2015-11-06       Impact factor: 2.840

Review 2.  ICT technologies as new promising tools for the managing of frailty: a systematic review.

Authors:  Alessia Gallucci; Pietro Davide Trimarchi; Carlo Abbate; Cosimo Tuena; Elisa Pedroli; Fabrizia Lattanzio; Marco Stramba-Badiale; Matteo Cesari; Fabrizio Giunco
Journal:  Aging Clin Exp Res       Date:  2020-07-23       Impact factor: 3.636

3.  Metrics extracted from a single wearable sensor during sit-stand transitions relate to mobility impairment and fall risk in people with multiple sclerosis.

Authors:  Lindsey J Tulipani; Brett Meyer; Dale Larie; Andrew J Solomon; Ryan S McGinnis
Journal:  Gait Posture       Date:  2020-06-20       Impact factor: 2.840

Review 4.  Preventing falls: the use of machine learning for the prediction of future falls in individuals without history of fall.

Authors:  Ioannis Bargiotas; Danping Wang; Juan Mantilla; Flavien Quijoux; Albane Moreau; Catherine Vidal; Remi Barrois; Alice Nicolai; Julien Audiffren; Christophe Labourdette; François Bertin-Hugaul; Laurent Oudre; Stephane Buffat; Alain Yelnik; Damien Ricard; Nicolas Vayatis; Pierre-Paul Vidal
Journal:  J Neurol       Date:  2022-07-11       Impact factor: 6.682

Review 5.  Regulation of DAPK1 by Natural Products: An Important Target in Treatment of Stroke.

Authors:  Tayebeh Noori; Samira Shirooie; Antoni Sureda; Eduardo Sobarzo-Sanchez; Ahmad Reza Dehpour; Marianela Saldías; Esra Küpeli Akkol
Journal:  Neurochem Res       Date:  2022-06-08       Impact factor: 4.414

6.  Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis.

Authors:  Lindsey J Tulipani; Brett Meyer; Dakota Allen; Andrew J Solomon; Ryan S McGinnis
Journal:  Gait Posture       Date:  2022-02-23       Impact factor: 2.746

7.  The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis.

Authors:  Lindsey J Tulipani; Brett Meyer; Samantha Fox; Andrew J Solomon; Ryan S Mcginnis
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2022-05-16       Impact factor: 4.528

8.  Comparison of kinematic variables obtained by inertial sensors among stroke survivors and healthy older adults in the Functional Reach Test: cross-sectional study.

Authors:  José Antonio Merchán-Baeza; Manuel González-Sánchez; Antonio Ignacio Cuesta-Vargas
Journal:  Biomed Eng Online       Date:  2015-05-30       Impact factor: 2.819

Review 9.  How wearable sensors have been utilised to evaluate frailty in older adults: a systematic review.

Authors:  Grainne Vavasour; Oonagh M Giggins; Julie Doyle; Daniel Kelly
Journal:  J Neuroeng Rehabil       Date:  2021-07-08       Impact factor: 4.262

10.  Older Compared With Younger Adults Performed 467 Fewer Sit-to-Stand Trials, Accompanied by Small Changes in Muscle Activation and Voluntary Force.

Authors:  Paulo Cezar Rocha Dos Santos; Claudine J C Lamoth; Lilian Teresa Bucken Gobbi; Inge Zijdewind; Fabio Augusto Barbieri; Tibor Hortobágyi
Journal:  Front Aging Neurosci       Date:  2021-06-21       Impact factor: 5.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.