Literature DB >> 23791354

Design of anthropomorphic flow phantoms based on rapid prototyping of compliant vessel geometries.

Simon S M Lai1, Billy Y S Yiu, Alexander K K Poon, Alfred C H Yu.   

Abstract

Anatomically realistic flow phantoms are essential experimental tools for vascular ultrasound. Here we describe how these flow phantoms can be efficiently developed via a rapid prototyping (RP) framework that involves direct fabrication of compliant vessel geometries. In this framework, anthropomorphic vessel models were drafted in computer-aided design software, and they were fabricated using stereolithography (one type of RP). To produce elastic vessels, a compliant photopolymer was used for stereolithography. We fabricated a series of compliant, diseased carotid bifurcation models with eccentric stenosis (50%) and plaque ulceration (types I and III), and they were used to form thin-walled flow phantoms by coupling the vessels to an agar-based tissue-mimicking material. These phantoms were found to yield Doppler spectrograms with significant spectral broadening and color flow images with mosaic patterns, as typical of disturbed flow under stenosed and ulcerated disease conditions. Also, their wall distension behavior was found to be similar to that observed in vivo, and this corresponded with the vessel wall's average elastic modulus (391 kPa), which was within the nominal range for human arteries. The vessel material's acoustic properties were found to be sub-optimal: the estimated average acoustic speed was 1801 m/s, and the attenuation coefficient was 1.58 dB/(mm·MHz(n)) with a power-law coefficient of 0.97. Such an acoustic mismatch nevertheless did not notably affect our Doppler spectrograms and color flow image results. These findings suggest that phantoms produced from our design framework have the potential to serve as ultrasound-compatible test beds that can simulate complex flow dynamics similar to those observed in real vasculature.
Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Anthropomorphic flow phantom; Compliant vessels; Rapid prototyping; Stereolithography; Vascular ultrasound

Mesh:

Year:  2013        PMID: 23791354     DOI: 10.1016/j.ultrasmedbio.2013.03.015

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models.

Authors:  Anderson Chun On Tsang; Simon Sui Man Lai; Wai Choi Chung; Abraham Yik Sau Tang; Gilberto Ka Kit Leung; Alexander Kai Kei Poon; Alfred Cheuk Hang Yu; Kwok Wing Chow
Journal:  Ultrasonography       Date:  2015-01-31

Review 2.  A Brief Review for Common Doppler Ultrasound Flow Phantoms.

Authors:  Sabri M Shalbi; Ammar A Oglat; Balid Albarbar; Fuzi Elkut; M A Qaeed; Ali Abu Arra
Journal:  J Med Ultrasound       Date:  2020-06-02

Review 3.  Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat; Omar F Farhat; Batool N Alkhateb; Raed Abdalrheem; Muntaser S Ahmad; Mohammed Y M Abujazar
Journal:  J Med Ultrasound       Date:  2018-05-07

Review 4.  Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound.

Authors:  Valeria Filippou; Charalampos Tsoumpas
Journal:  Med Phys       Date:  2018-06-22       Impact factor: 4.071