Literature DB >> 23791149

Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers.

Maria Luisa Feo1, Enrique Barón, Diana S Aga, Ethel Eljarrat, Damià Barceló.   

Abstract

Recently, hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have emerged as environmentally relevant pollutants due to recent reports of their natural production and metabolism. Recent mechanistic studies in human and rats have shown that some OH-PBDEs are more potent than parent compounds (PBDEs) and may contribute substantially to neurodevelopmental disorders by direct neurotoxicity, or indirectly through altered thyroid disruption. However, analytical methodologies for determination of OH-PBDEs are currently limited. In this study a robust liquid chromatography-electrospray tandem triple quadrupole-linear ion trap mass spectrometer (LC-ESI-QqLIT-MS-MS) in negative mode method was developed for the determination of eleven OH-tri- to OH-hexa-PBDEs. Two different columns were tested and compared for chromatographic separation: a C18 BetaBasic and a Purospher STAR RP 18, working at pH 8 and 10, respectively. Mobile phase (acetonitrile:water) was optimized by changing the pH of the aqueous phase and the concentration of the organic modifier (methanol). The MS-MS parameters (declustering potential (DP), collision energy (CE) and cell exit potential (CXP)) were optimized. Selected reaction monitoring (SRM) was used in order to increase sensitivity. Two SRM transitions ([M-H](-)>[Br](-)) were selected for each OH-PBDE, one for quantification and the second one for confirmation. Under the optimized conditions, the instrumental limits of detection were between 0.17 and 0.72injectedpg. The method provided good linearity (r>0.99 for a concentration range of 0.30-100ng/mL), accuracy and precision (%Dev and %RSD≤20% for intra- and inter-assays).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Endocrine disruptor; Flame retardants; OH-PBDE; Polybrominated diphenyl ethers; Triple quadrupole-linear ion trap

Mesh:

Substances:

Year:  2013        PMID: 23791149     DOI: 10.1016/j.chroma.2013.05.062

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Isomer Separation of Polybrominated Diphenyl Ether Metabolites using nanoESI-TIMS-MS.

Authors:  Kendra J Adams; Dennise Montero; Diana Aga; Francisco Fernandez-Lima
Journal:  Int J Ion Mobil Spectrom       Date:  2016-04-21

2.  Development of an analytical method to quantify PBDEs, OH-BDEs, HBCDs, 2,4,6-TBP, EH-TBB, and BEH-TEBP in human serum.

Authors:  Craig M Butt; Marie Lynn Miranda; Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2016-02-10       Impact factor: 4.142

3.  Evaporative derivatization of phenols with 2-sulfobenzoic anhydride for detection by matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Yuanyuan Yao; Poguang Wang; Roger Giese
Journal:  Rapid Commun Mass Spectrom       Date:  2014-03-30       Impact factor: 2.419

Review 4.  Advances in Instrumental Analysis of Brominated Flame Retardants: Current Status and Future Perspectives.

Authors:  Mohamed Abou-Elwafa Abdallah
Journal:  Int Sch Res Notices       Date:  2014-10-28

5.  Quantification of Hydroxylated Polybrominated Diphenyl Ethers (OH-BDEs), Triclosan, and Related Compounds in Freshwater and Coastal Systems.

Authors:  Jill F Kerrigan; Daniel R Engstrom; Donald Yee; Charles Sueper; Paul R Erickson; Matthew Grandbois; Kristopher McNeill; William A Arnold
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.