Repeatability of digital image correlation for measurement of surface strains in composite long bones.

Sami P Väänänen1, Saber Amin Yavari, Harrie Weinans, Amir Abbas Zadpoor, Jukka S Jurvelin, Hanna Isaksson.   

Abstract

Digital image correlation (DIC) can measure full-field surface strains during mechanical testing of hard and soft tissues. When compared to traditional methods, such as strain gauges, DIC offers larger validation data (∼50,000 points) for, e.g., finite element models. Our main aim was to evaluate the repeatability of surface strain measurements with DIC during compressive testing of composite femurs mimicking human bones. We also studied the similarity of the composite femur samples using CT. Composite femurs were chosen as test material to minimize the uncertainties associated with the use of cadaveric tissues and to understand the variability of the DIC measurement itself. Six medium-sized fourth generation composite human proximal femora (Sawbones) were CT imaged and mechanically tested in stance configuration. The force-displacement curves were recorded and the 3D surface strains were measured with DIC on the anterior surface of the femurs. Five femurs fractured at the neck-trochanter junction and one at the site below the minor trochanter. CT image of this bone showed an air cavity at the initial fracture site. All femurs fractured through a sudden brittle crack. The fracture force for the composite bones was 5751±650N (mean±SD). The maximum von Mises strain during the fractures was 2.4±0.8%. Noise in one experiment was 5-30µε. When applied loads were equalized the variation in strains between the bones was 20-25%, and when the maximum strains were equalized, variation in the other regions was 5-10%. DIC showed that the ability of nominally identical composite bones to bear high strains and loads before fracturing may vary between the samples.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Digital image correlation; Mechanical loading; Proximal femur; Surface strains

Mesh:

Year:  2013        PMID: 23791085     DOI: 10.1016/j.jbiomech.2013.05.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Study of Mechanical Behavior in Epiphyseal Fracture Treated by Reduction and Cement Injection: No Immediate Post-Operative Weight-Bearing but Only Passive and Active Mobilization Should be Advised.

Authors:  A Moufid; P Bokam; G Harika-Germaneau; M Severyns; L Caillé; V Valle; T Vendeuvre; A Germaneau
Journal:  Front Bioeng Biotechnol       Date:  2022-07-04

2.  Experimental Investigation on the Mechanical Behavior of Bovine Bone Using Digital Image Correlation Technique.

Authors:  Yuxi Chen; Diansen Yang; Yongshang Ma; XianJun Tan; Zhan Shi; Taoran Li; Haipeng Si
Journal:  Appl Bionics Biomech       Date:  2015-02-15       Impact factor: 1.781

3.  Reverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant.

Authors:  Elise J Martin; Thomas R Duquin; Mark T Ehrensberger
Journal:  J Shoulder Elb Arthroplast       Date:  2021-06-13

4.  Does a PEEK Femoral TKA Implant Preserve Intact Femoral Surface Strains Compared With CoCr? A Preliminary Laboratory Study.

Authors:  Kathryn E Rankin; Alexander S Dickinson; Adam Briscoe; Martin Browne
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

5.  The effect of implant position on bone strain following lateral unicompartmental knee arthroplasty: A Biomechanical Model Using Digital Image Correlation.

Authors:  A M Ali; S D S Newman; P A Hooper; C M Davies; J P Cobb
Journal:  Bone Joint Res       Date:  2017-08       Impact factor: 5.853

6.  The effect of rotational degree and routine activity on the risk of collapse in transtrochanteric rotational osteotomy for osteonecrosis of the femoral head-a finite element analysis.

Authors:  Pusheng Xie; Yuping Deng; Jinchuan Tan; Mian Wang; Yang Yang; Hanbin Ouyang; Wenhua Huang
Journal:  Med Biol Eng Comput       Date:  2020-02-03       Impact factor: 2.602

7.  Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation.

Authors:  I Tatani; P Megas; A Panagopoulos; I Diamantakos; Ph Nanopoulos; Sp Pantelakis
Journal:  Biomed Eng Online       Date:  2020-08-19       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.