Literature DB >> 23790831

Synthesis and application of a new functionalized resin for use in an on-line, solid phase extraction system for the determination of trace elements in waters and reference cereal materials by flame atomic absorption spectrometry.

Cennet Karadaş1, Onur Turhan, Derya Kara.   

Abstract

The synthesis and characterization of the resin Amberlite XAD-4 functionalized with 2,6-pyridinedicarboxaldehyde and its application in an on-line system for the preconcentration of cadmium, cobalt, copper, lead and manganese prior to determination using flame atomic absorption spectrometry (FAAS) is proposed. Metal ions retained on the modified resin were eluted using 1.0 mol L(-1) HNO3 solution and aspirated directly to the nebulizer-burner system of a FAAS instrument using a flow injection system. Detection limits (3σ) were determined to be 0.13 μg L(-1) for Cd, 0.29 μg L(-1) for Cu, 0.23 μg L(-1) for Mn, 0.58 μg L(-1) for Co and 2.19 μg L(-1) for Pb using a 10 mL of water sample loading volume. The limits of detection would be 100 times higher with units of μg kg(-1) for the solid samples in which their dilution ratios as (volume/weight) were 100. Enrichment factors ranged from 23.6 to 28.9 (for Co and Mn, respectively). The proposed method was successfully applied to determination of the analytes in natural water samples and certified reference materials.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23790831     DOI: 10.1016/j.foodchem.2013.03.042

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  4 in total

1.  Evaluation of cadmium in greenhouse soils and agricultural products of Jiroft (Iran) using microwave digestion prior to atomic absorption spectrometry determination.

Authors:  Daryoush Afzali; Fariba Fathirad; Zahra Afzali; Seyed Mohammad Javad Majdzadeh-Kermani
Journal:  Environ Monit Assess       Date:  2015-02-20       Impact factor: 2.513

2.  Magnetic nanoparticle based solid-phase extraction of heavy metal ions: A review on recent advances.

Authors:  Maryam Hemmati; Maryam Rajabi; Alireza Asghari
Journal:  Mikrochim Acta       Date:  2018-02-06       Impact factor: 5.833

3.  A Novel Glass Fiber Coated with Sol-Gel Poly-Diphenylsiloxane Sorbent for the On-Line Determination of Toxic Metals Using Flow Injection Column Preconcentration Platform Coupled with Flame Atomic Absorption Spectrometry.

Authors:  Eleni Lazaridou; Abuzar Kabir; Kenneth G Furton; Aristidis Anthemidis
Journal:  Molecules       Date:  2020-12-22       Impact factor: 4.411

4.  Synthesis of a novel hexaazatriphenylene derivative for the selective detection of copper ions in aqueous solution.

Authors:  Tahseen S Saeed; Dinesh Maddipatla; Binu B Narakathu; Sarah S Albalawi; Sherine O Obare; Massood Z Atashbar
Journal:  RSC Adv       Date:  2019-12-02       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.