Literature DB >> 23790301

Development of a colorimetric microfluidic pH sensor for autonomous seawater measurements.

Victoire M C Rérolle1, Cedric F A Floquet, Andy J K Harris, Matt C Mowlem, Richard R G J Bellerby, Eric P Achterberg.   

Abstract

High quality carbonate chemistry measurements are required in order to fully understand the dynamics of the oceanic carbonate system. Seawater pH data with good spatial and temporal coverage are particularly critical to apprehend ocean acidification phenomena and their consequences. There is a growing need for autonomous in situ instruments that measure pH on remote platforms. Our aim is to develop an accurate and precise autonomous in situ pH sensor for long term deployment on remote platforms. The widely used spectrophotometric pH technique is capable of the required high-quality measurements. We report a key step towards the miniaturization of a colorimetric pH sensor with the successful implementation of a simple microfluidic design with low reagent consumption. The system is particularly adapted to shipboard deployment: high quality data was obtained over a period of more than a month during a shipboard deployment in northwest European shelf waters, and less than 30 mL of indicator was consumed. The system featured a short term precision of 0.001 pH (n=20) and an accuracy within the range of a certified Tris buffer (0.004 pH). The quality of the pH system measurements have been checked using various approaches: measurements of certified Tris buffer, measurement of certified seawater for DIC and TA, comparison of measured pH against calculated pH from pCO2, DIC and TA during the cruise in northwest European shelf waters. All showed that our measurements were of high quality. The measurements were made close to in situ temperature (+0.2°C) in a sampling chamber which had a continuous flow of the ship's underway seawater supply. The optical set up was robust and relatively small due to the use of an USB mini-spectrometer, a custom made polymeric flow cell and an LED light source. The use of a three wavelength LED with detection that integrated power across the whole of each LED output spectrum indicated that low wavelength resolution detectors can be used instead of the current USB mini spectrophotometer. Artefacts due to the polychromatic light source and inhomogeneity in the absorption cell are shown to have a negligible impact on the data quality. The next step in the miniaturization of the sensor will be the incorporation of a photodiode as detector to replace the spectrophotometer. Crown
Copyright © 2013. Published by Elsevier B.V. All rights reserved.

Entities:  

Year:  2013        PMID: 23790301     DOI: 10.1016/j.aca.2013.05.008

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  9 in total

1.  Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications.

Authors:  Andreas Steinegger; Otto S Wolfbeis; Sergey M Borisov
Journal:  Chem Rev       Date:  2020-11-04       Impact factor: 60.622

2.  All Silica Micro-Fluidic Flow Injection Sensor System for Colorimetric Chemical Sensing.

Authors:  Vedran Budinski; Denis Donlagic
Journal:  Sensors (Basel)       Date:  2021-06-14       Impact factor: 3.576

3.  Characterization of meta-Cresol Purple for spectrophotometric pH measurements in saline and hypersaline media at sub-zero temperatures.

Authors:  Socratis Loucaides; Victoire M C Rèrolle; Stathys Papadimitriou; Hilary Kennedy; Matthew C Mowlem; Andrew G Dickson; Martha Gledhill; Eric P Achterberg
Journal:  Sci Rep       Date:  2017-05-30       Impact factor: 4.379

4.  Improving the Sensitivity of Solid-Contact Ion-Selective Electrodes by Using Coulometric Signal Transduction.

Authors:  Tingting Han; Ulriika Mattinen; Johan Bobacka
Journal:  ACS Sens       Date:  2019-03-19       Impact factor: 7.711

Review 5.  Observing Changes in Ocean Carbonate Chemistry: Our Autonomous Future.

Authors:  Seth M Bushinsky; Yuichiro Takeshita; Nancy L Williams
Journal:  Curr Clim Change Rep       Date:  2019-05-07

Review 6.  Autonomous and In Situ Ocean Environmental Monitoring on Optofluidic Platform.

Authors:  Fang Wang; Jiaomeng Zhu; Longfei Chen; Yunfeng Zuo; Xuejia Hu; Yi Yang
Journal:  Micromachines (Basel)       Date:  2020-01-08       Impact factor: 2.891

7.  Lab-on-chip analyser for the in situ determination of dissolved manganese in seawater.

Authors:  Felix Geißler; Eric P Achterberg; Alexander D Beaton; Mark J Hopwood; Mario Esposito; Matt C Mowlem; Douglas P Connelly; Douglas Wallace
Journal:  Sci Rep       Date:  2021-01-27       Impact factor: 4.379

8.  A Microfluidic pH Measurement Device with a Flowing Liquid Junction.

Authors:  Akira Yamada; Miho Suzuki
Journal:  Sensors (Basel)       Date:  2017-07-04       Impact factor: 3.576

9.  High Resolution pH Measurements Using a Lab-on-Chip Sensor in Surface Waters of Northwest European Shelf Seas.

Authors:  Victoire M C Rérolle; Eric P Achterberg; Mariana Ribas-Ribas; Vassilis Kitidis; Ian Brown; Dorothee C E Bakker; Gareth A Lee; Matthew C Mowlem
Journal:  Sensors (Basel)       Date:  2018-08-10       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.