Literature DB >> 23790286

Electrochemical sensor based on chlorohemin modified molecularly imprinted microgel for determination of 2,4-dichlorophenol.

Jin Zhang1, Jianping Lei, Huangxian Ju, Chaoying Wang.   

Abstract

A newly designed molecularly imprinted polymer (MIP) was synthesized and successfully utilized as a recognition element of an amperometric sensor for 2,4-dichlorophenol (2,4-DCP) detection. The MIP with a well-defined structure could imitate the dehalogenative function of the natural enzyme chloroperoxidase for 2,4-DCP. Imprinted sensor was fabricated in situ on a glassy carbon electrode surface by drop-coating the 2,4-DCP imprinted microgel suspension and chitosan/Nafion mixture. Under optimized conditions, the sensor showed a linear response in the range of 5.0-100 μmol L(-1) with a detection limit of 1.6 μmol L(-1). Additionally, the imprinted sensor demonstrated higher affinity to target 2,4-DCP over competitive chlorophenolic compounds than non-imprinted sensor. It also exhibited good stability and acceptable repeatability. The proposed sensor could be used for the determination of 2,4-DCP in water samples with the recoveries of 96.2-111.8%, showing a promising potential in practical application.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23790286     DOI: 10.1016/j.aca.2013.05.012

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  An electrochemical sensor based on copper-based metal-organic framework-reduced graphene oxide composites for determination of 2,4-dichlorophenol in water.

Authors:  Manh B Nguyen; Vu Thi Hong Nhung; Vu Thi Thu; Dau Thi Ngoc Nga; Thuan Nguyen Pham Truong; Hoang Truong Giang; Pham Thi Hai Yen; Pham Hong Phong; Tuan A Vu; Vu Thi Thu Ha
Journal:  RSC Adv       Date:  2020-11-19       Impact factor: 4.036

Review 2.  MIPs and Aptamers for Recognition of Proteins in Biomimetic Sensing.

Authors:  Marcus Menger; Aysu Yarman; Júlia Erdőssy; Huseyin Bekir Yildiz; Róbert E Gyurcsányi; Frieder W Scheller
Journal:  Biosensors (Basel)       Date:  2016-07-18

3.  Quantitative determination and toxicity evaluation of 2,4-dichlorophenol using poly(eosin Y)/hydroxylated multi-walled carbon nanotubes modified electrode.

Authors:  Xiaolin Zhu; Kexin Zhang; Chengzhi Wang; Jiunian Guan; Xing Yuan; Baikun Li
Journal:  Sci Rep       Date:  2016-12-12       Impact factor: 4.379

Review 4.  How Reliable Is the Electrochemical Readout of MIP Sensors?

Authors:  Aysu Yarman; Frieder W Scheller
Journal:  Sensors (Basel)       Date:  2020-05-08       Impact factor: 3.576

5.  Prenatal exposure to organophosphate and pyrethroid insecticides and the herbicide 2,4-dichlorophenoxyacetic acid and size at birth in urban pregnant women.

Authors:  Arin A Balalian; Xinhua Liu; Julie B Herbstman; Sharon Daniel; Robin Whyatt; Virginia Rauh; Antonia M Calafat; Ronald Wapner; Pam Factor-Litvak
Journal:  Environ Res       Date:  2021-06-24       Impact factor: 8.431

  5 in total