PURPOSE: At high magnetic field strengths (B(0) ≥ 3 T), the shorter radiofrequency wavelength produces an inhomogeneous distribution of the transmit magnetic field. This can lead to variable contrast across the brain which is particularly pronounced in T(2) -weighted imaging that requires multiple radiofrequency pulses. To obtain T(2) -weighted images with uniform contrast throughout the whole brain at 7 T, short (2-3 ms) 3D tailored radiofrequency pulses (kT -points) were integrated into a 3D variable flip angle turbo spin echo sequence. METHODS: The excitation and refocusing "hard" pulses of a variable flip angle turbo spin echo sequence were replaced with kT -point pulses. Spatially resolved extended phase graph simulations and in vivo acquisitions at 7 T, utilizing both single channel and parallel-transmit systems, were used to test different kT -point configurations. RESULTS: Simulations indicated that an extended optimized k-space trajectory ensured a more homogeneous signal throughout images. In vivo experiments showed that high quality T(2) -weighted brain images with uniform signal and contrast were obtained at 7 T by using the proposed methodology. CONCLUSION: This work demonstrates that T(2) -weighted images devoid of artifacts resulting from B(1)(+) inhomogeneity can be obtained at high field through the optimization of extended kT -point pulses.
PURPOSE: At high magnetic field strengths (B(0) ≥ 3 T), the shorter radiofrequency wavelength produces an inhomogeneous distribution of the transmit magnetic field. This can lead to variable contrast across the brain which is particularly pronounced in T(2) -weighted imaging that requires multiple radiofrequency pulses. To obtain T(2) -weighted images with uniform contrast throughout the whole brain at 7 T, short (2-3 ms) 3D tailored radiofrequency pulses (kT -points) were integrated into a 3D variable flip angle turbo spin echo sequence. METHODS: The excitation and refocusing "hard" pulses of a variable flip angle turbo spin echo sequence were replaced with kT -point pulses. Spatially resolved extended phase graph simulations and in vivo acquisitions at 7 T, utilizing both single channel and parallel-transmit systems, were used to test different kT -point configurations. RESULTS: Simulations indicated that an extended optimized k-space trajectory ensured a more homogeneous signal throughout images. In vivo experiments showed that high quality T(2) -weighted brain images with uniform signal and contrast were obtained at 7 T by using the proposed methodology. CONCLUSION: This work demonstrates that T(2) -weighted images devoid of artifacts resulting from B(1)(+) inhomogeneity can be obtained at high field through the optimization of extended kT -point pulses.
Authors: Xiaoping Wu; Edward J Auerbach; An T Vu; Steen Moeller; Pierre-François Van de Moortele; Essa Yacoub; Kâmil Uğurbil Journal: Neuroimage Date: 2018-09-17 Impact factor: 6.556
Authors: Florent Eggenschwiler; Kieran Robert O'Brien; Daniel Gallichan; Rolf Gruetter; José Pedro Marques Journal: MAGMA Date: 2016-04-08 Impact factor: 2.310
Authors: Linda Marrakchi-Kacem; Alexandre Vignaud; Julien Sein; Johanne Germain; Thomas R Henry; Cyril Poupon; Lucie Hertz-Pannier; Stéphane Lehéricy; Olivier Colliot; Pierre-François Van de Moortele; Marie Chupin Journal: MAGMA Date: 2016-05-02 Impact factor: 2.310
Authors: M Arcan Ertürk; Xiaoping Wu; Yiğitcan Eryaman; Pierre-François Van de Moortele; Edward J Auerbach; Russell L Lagore; Lance DelaBarre; J Thomas Vaughan; Kâmil Uğurbil; Gregor Adriany; Gregory J Metzger Journal: Magn Reson Med Date: 2016-10-21 Impact factor: 4.668
Authors: Alessandro Sbrizzi; Hans Hoogduin; Joseph V Hajnal; Cornelis A T van den Berg; Peter R Luijten; Shaihan J Malik Journal: Magn Reson Med Date: 2016-01-22 Impact factor: 4.668