Literature DB >> 237871

Saturation dependency of the Bohr effect: interactions among H-+, CO2, and DPG.

M P Hlastala, R D Woodson.   

Abstract

The Bohr effect was measured in normal whole blood and in blood with low DPG concentration as a function of oxygen saturation. pH was changed by varying CO2 concentration (CO2 Bohr effect) or by addition of isotonic NaOH or HC1 at constant PCO2 (fixed acid Bohr effect). At nornal DPG concentration CO2 Bohr effect was -0.52 at 50% blood oxygen saturation, increasing in magnitude at lower saturation and decreasing in magnitude at higher saturation. In DPG depleted blood with base excess (BE) similar to 0 meq/1, there was similar dependence of CO2 Bohr effect on oxygen saturation. At BE similar to -10 meq/1, influence of saturation was comparable, but the magnitude of the Bohr effect was markedly increased at all saturations. Fixed acid Bohr effect at normal DPG concentration was -0.45 at saturations of 50-90% but decreased at lower saturations. In DPG-depleted blood fixed acid Bohr effect averaged about -0.33 with minimal variation with saturation. Influence of DPG on oxygen affinity was greater at intermediate saturations and less at saturations below 20% and above 80%. Effect of CO2, independent of pH, was many fold greater at lower oxygen saturations than at higher saturations. These results support the suggestion that the alpha chain of hemoglobin is the site of the initial oxygenation reaction. Physiologically they indicate that the relative contribution of CO2 and fixed acid, as well as the level of oxygen saturation and DPG concentration, may be important in determining PO2 of capillary blood and resulting oxygen delivery.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 237871     DOI: 10.1152/jappl.1975.38.6.1126

Source DB:  PubMed          Journal:  J Appl Physiol        ISSN: 0021-8987            Impact factor:   3.531


  10 in total

1.  Effects of inositol hexaphosphate on the Bohr effect induced by CO2 and fixed acids in chicken hemoglobin.

Authors:  J P Weingarten; H S Rollema; C Bauer; P Scheid
Journal:  Pflugers Arch       Date:  1978-11-14       Impact factor: 3.657

2.  Dual effect of 2,3-diphosphoglycerate on the Bohr effects of human blood.

Authors:  J Duhm
Journal:  Pflugers Arch       Date:  1976-05-06       Impact factor: 3.657

3.  Simultaneous blood-tissue exchange of oxygen, carbon dioxide, bicarbonate, and hydrogen ion.

Authors:  Ranjan K Dash; James B Bassingthwaighte
Journal:  Ann Biomed Eng       Date:  2006-05-30       Impact factor: 3.934

4.  Bohr effect induced by CO2 and fixed acid at various levels of O2 saturation in duck blood.

Authors:  M Meyer; J P Holle; P Scheid
Journal:  Pflugers Arch       Date:  1978-09-29       Impact factor: 3.657

5.  Chloride binding and the Bohr effect of human fetal erythrocytes and HbFII solutions.

Authors:  C Poyart; E Bursaux; P Guesnon; B Teisseire
Journal:  Pflugers Arch       Date:  1978-09-06       Impact factor: 3.657

6.  Comparative effects of CO2 on the affinity for O2 of fetal and adult erythrocytes.

Authors:  E Bursaux; C Poyart; P Guesnon; B Teisseire
Journal:  Pflugers Arch       Date:  1979-01-31       Impact factor: 3.657

7.  Fixed acid and carbon dioxide Bohr effects as functions of hemoglobin-oxygen saturation and erythrocyte pH in the blood of the frog, Rana temporaria.

Authors:  R M Wells; R E Weber
Journal:  Pflugers Arch       Date:  1985-01       Impact factor: 3.657

8.  Hemoglobin oxygen affinity in patients suffering from arterial occlusive disease of the legs.

Authors:  K M Braumann; W Kleemann; U Martens; N Maassen; U Maass; W Schmidt; D Böning
Journal:  Klin Wochenschr       Date:  1988-05-02

9.  Temperature and oxygenation of human blood at constant total CO2 content.

Authors:  M Castaing; M Sinet
Journal:  Pflugers Arch       Date:  1980-07       Impact factor: 3.657

10.  A comparative study of the kinetics of the Bohr effect in vertebrates.

Authors:  T H Maren; E R Swenson
Journal:  J Physiol       Date:  1980-06       Impact factor: 5.182

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.