Differences in blood pressure levels obtained by auscultatory and oscillometric methods.

M G Weaver1, M K Park, D H Lee.   

Abstract

Levels of blood pressure measured by the conventional auscultatory method were compared with those measured by the Dinamap Monitor (Dinamap Monitor 1846 SX, Critikon Inc, Tampa, Fla), an oscillometric device. Triplicate measurements were obtained by the two methods 10 to 15 minutes apart in 381 seated fifth-grade children, ages 10 to 13 years. The width of the air bladder of the blood pressure cuff was selected to be 40% to 50% of the circumference of the upper arm. The mean systolic and diastolic pressures (at the fourth phase of Korotkoff sounds) by the auscultatory method were 6.4 mm Hg lower and 8.7 mm Hg higher than the oscillometric systolic and diastolic blood pressures, respectively. The findings of this study suggest that published normative levels of auscultatory blood pressure may be inappropriate as a standard when blood pressure measurement is obtained by the Dinamap Monitor. Until a new set of normative Dinamap blood pressure levels becomes available, one should use equations (A = 12.8 + 0.82D for systolic, and A = 34.3 + 0.54D for diastolic blood pressures at the fourth phase of Korotkoff sounds, where A is auscultatory blood pressure and D is Dinamap blood pressure) to predict auscultatory blood pressures before Dinamap blood pressures are compared with normative auscultatory blood pressure levels.

Entities:  

Mesh:

Year:  1990        PMID: 2378339     DOI: 10.1001/archpedi.1990.02150320075031

Source DB:  PubMed          Journal:  Am J Dis Child        ISSN: 0002-922X


  11 in total

1.  Use of oscillometric devices for the measurement of blood pressure-comparison with the gold standard.

Authors:  Nivedita Kamath; B Ramakrishna Goud; Kishore D Phadke; Arpana Iyengar
Journal:  Indian J Pediatr       Date:  2011-11-05       Impact factor: 1.967

2.  Oscillometric blood pressure standards for children.

Authors:  M K Park; S W Menard; J Schoolfield
Journal:  Pediatr Cardiol       Date:  2005 Sep-Oct       Impact factor: 1.655

3.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

4.  Clinical evaluation of the oscillometric blood pressure monitor in adults and children based on the 1992 AAMI SP-10 standards.

Authors:  J Ling; Y Ohara; Y Orime; G P Noon; S Takatani
Journal:  J Clin Monit       Date:  1995-03

5.  The effect of sleeved arms on oscillometric blood pressure measurement.

Authors:  D R Holleman; E C Westman; D C McCrory; D L Simel
Journal:  J Gen Intern Med       Date:  1993-06       Impact factor: 5.128

6.  Clinical trial of extended-release felodipine in pediatric essential hypertension.

Authors:  Howard Trachtman; Rachel Frank; John D Mahan; Ronald Portman; Irene Restaino; Tej K Matoo; Conrad Tou; Michael Klibaner
Journal:  Pediatr Nephrol       Date:  2003-04-17       Impact factor: 3.714

7.  'Home hypertension': exploring the inverse white coat response.

Authors:  N Donner-Banzhoff; Y Chan; J P Szalai; J Hilditch
Journal:  Br J Gen Pract       Date:  1998-08       Impact factor: 5.386

8.  Twenty-four hour blood pressure monitoring in healthy children.

Authors:  F Krull; T Buck; G Offner; J Brodehl
Journal:  Eur J Pediatr       Date:  1993-07       Impact factor: 3.183

9.  High blood pressure in school children: prevalence and risk factors.

Authors:  Ximena Urrutia-Rojas; Christie U Egbuchunam; Sejong Bae; John Menchaca; Manuel Bayona; Patrick A Rivers; Karan P Singh
Journal:  BMC Pediatr       Date:  2006-11-16       Impact factor: 2.125

10.  Oscillometric blood pressure reference values of African full-term neonates in their first days postpartum.

Authors:  W E Sadoh; S E Ibhanesebhor
Journal:  Cardiovasc J Afr       Date:  2009 Nov-Dec       Impact factor: 1.167

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.