Literature DB >> 23780226

Determination of chlorobenzenes in water samples based on fully automated microextraction by packed sorbent coupled with programmed temperature vaporization-gas chromatography-mass spectrometry.

Gloria Grueiro Noche1, María Esther Fernández Laespada, José Luis Pérez Pavón, Bernardo Moreno Cordero, Soledad Muniategui Lorenzo.   

Abstract

A fully automated method consisting of microextraction by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS) has been developed to determine the 12 chlorobenzene congeners (chlorobenzene; 1,2-, 1,3-, and 1,4-dichlorobenzene; 1,2,3-, 1,2,4-, and 1,3,5-trichlorobenzene; 1,2,3,4-, 1,2,3,5-, and 1,2,4,5-tetrachlorobenzene; pentachlorobenzene; and hexachlorobenzene) in water samples. The effects of the variables on MEPS extraction, using a C18 sorbent, and the instrumental PTV conditions were studied. The internal standard 1,4-dichlorobenzene d4 was used as a surrogate. The proposed method afforded good reproducibility, with relative standard deviations (RSD %) lower than 12%. The limits of detection varied between 0.0003 μg L(-1) for 1,2,3,4-tetrachlorobenzene and 0.07 μg L(-1) for 1,3- and 1,4-dichlorobenzene, while those of quantification varied between 0.001 μg L(-1) and 0.2 μg L(-1) for the same compounds. Accuracy of the proposed method was confirmed by applying it to the determination of chlorobenzenes in different spiked water samples, including river, reservoir, and effluent wastewater.

Entities:  

Year:  2013        PMID: 23780226     DOI: 10.1007/s00216-013-7112-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Determination of Benzophenones in Water and Cosmetics Samples: A Comparison of Solid-Phase Extraction and Microextraction by Packed Sorbent Methods.

Authors:  Grażyna Wejnerowska; Izabela Narloch
Journal:  Molecules       Date:  2021-11-16       Impact factor: 4.411

2.  Comparison of different serum sample extraction methods and their suitability for mass spectrometry analysis.

Authors:  Thamir M Alshammari; Ahmed Ali Al-Hassan; Taibi B Hadda; Mohamad Aljofan
Journal:  Saudi Pharm J       Date:  2015-02-10       Impact factor: 4.330

3.  [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction].

Authors:  Jianan Wei; Molin Qin; Junchao Yang; Liu Yang
Journal:  Se Pu       Date:  2021-03
  3 in total