PURPOSE OF THE STUDY: A retrospective analysis of complications associated with surgical treatment of pelvic ring fractures. MATERIAL: Between 2004 and 2011 a total of 257 patients with pelvic ring fractures, 176 men and 81 women with an average age of 36 years, were treated. The average follow-up was 53 months (range, 13 to 108 months). AO type C fractures, which were most frequent, were recorded in 67%, type B fractures in 30% and type A fractures in 3% of the patients. Displaced unstable fractures or markedly displaced type A fractures of the pelvic ring were indicated for surgery.
RESULTS: Three types of complications were distinguished, i.e., intra-operative, early and late. Of a total of 40 intra-operative complications in 31 (16%) patients, the most frequent ones included malreduction in 14 patients (5%), nerve injury in 12 (5%), erroneous insertion of an implant in seven (3%) and vascular injury in six (2%) patients. Early post-operative complications requiring repeat surgery that were recorded in 15 patients (6%) were due to failure of osteosynthesis in seven patients, early wound infection in six, and haematoma which needed exploration in two patients. There were 25 late post-operative complications in 18 patients and they included fracture union with pelvic deformity in eight (3%) patients, chronic posterior pelvic pain in seven (3%), inguinal hernia through a scar in six (2%), pseudoarthrosis in three (1%) and late infection in one patient. DISCUSSION: The outcome of surgery depends on the fracture type, method of management and associated injuries; the patient's age and bone quality also play a role. Risk factors for the development of complications include markedly displaced and unstable pelvic ring fractures, open fractures, complex pelvic injury and associated injuries which do not allow for immediate definitive fracture stabilisation. Not every poor outcome is due to a complication per se or, the other way round, is exclusively related to the type of fracture. Many long-term sequelae arise from complex injuries. Because the anatomy of the pelvis is very complex, pelvic fractures are often associated with injury to the nerve structures and their management by reduction and fixation is difficult.
CONCLUSIONS: The characterisation and evaluation of complications associated with the management of pelvic ring fractures is problematic because it is difficult to distinguish which of them have been caused by pelvic ring fracture and associated injuries and which are due to surgical treatment. Although most complications arise from injury, the increasing role of surgery in their treatment leads to a higher rate of iatrogenic complications most frequently resulting from an improper surgical technique, including fracture reduction and/or fixation.

Entities:  

Mesh:

Year:  2013        PMID: 23777946

Source DB:  PubMed          Journal:  Acta Chir Orthop Traumatol Cech        ISSN: 0001-5415            Impact factor:   0.531


  6 in total

1.  Outcome and 2-Year Survival Rate in Elderly Patients With Lateral Compression Fractures of the Pelvis.

Authors:  Andreas Höch; Orkun Özkurtul; Philipp Pieroh; Christoph Josten; Jörg Böhme
Journal:  Geriatr Orthop Surg Rehabil       Date:  2016-12-14

2.  Factors affecting mortality and reoperations in high-energy pelvic fractures.

Authors:  Peyman Bakhshayesh; Lars Weidenhielm; Anders Enocson
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-04-19

3.  Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures.

Authors:  Tao Long; Kai-Nan Li; Jin-Hua Gao; Tian-Hu Liu; Jian-Song Mu; Xue-Jun Wang; Chao Peng; Zhi-Yong He
Journal:  Orthop Surg       Date:  2019-05-11       Impact factor: 2.071

4.  Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries.

Authors:  Jui-Ping Chen; Ping-Jui Tsai; Chun-Yi Su; I-Chuan Tseng; Ying-Chao Chou; I-Jung Chen; Pai-Wei Lee; Yi-Hsun Yu
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

5.  Multimodal Neuroelectrophysiological Monitoring Combined with Robot-Assisted Placement of a Transiliac-Transsacral Screw for the Treatment of Transforaminal Sacral Fractures.

Authors:  Pengfei Wang; Kun Yang; Huaguang Qi; Xinan Yan; Chen Fei; Xuemei Liu; Xing Wei; Hu Wang; Yahui Fu; Hongli Deng; Kun Zhang; Yan Zhuang
Journal:  Biomed Res Int       Date:  2022-07-23       Impact factor: 3.246

6.  Novel laparoscopic methods for inguinal hernia post pelvic fracture: A case report.

Authors:  Yusuke Tsunetoshi; Akihiro Usui; Koichi Inukai; Motohiko Yamada; Masanori Kawamoto; Hiroyuki Kayata; Koji Amano; Hideaki Yakushiji; Nobutaka Mukai; Yasuki Nakata; Junichiro Yokota
Journal:  Int J Surg Case Rep       Date:  2020-02-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.