Literature DB >> 23775453

Different thermal conductivity in drilling of cemented compared with cementless hip prostheses in the treatment of periprosthetic fractures of the proximal femur: an experimental biomechanical analysis.

Stephan Brand1, Johannes Klotz, Thomas Hassel, Maximilian Petri, Max Ettinger, Christian Krettek, Thomas Goesling, Friedrich-Wilhelm Bach.   

Abstract

PURPOSE: The purpose of this study was to evaluate the different temperature levels whilst drilling cemented and cementless hip prostheses implanted in bovine femora, and to evaluate the insulating function of the cement layer.
METHODS: Standard hip prostheses were implanted in bovine donor diaphyses, with or without a cement layer. Drilling was then performed using high-performance-cutting drills with a reinforced core, a drilling diameter of 5.5 mm and cooling channels through the tip of the drill for constantly applied internal cooling solution. An open type cooling model was used in this setup. Temperature was continuously measured by seven thermocouples placed around the borehole. Thermographic scans were also performed during drilling.
RESULTS: At the cemented implant surface, the temperature never surpassed 24.7 °C when constantly applied internal cooling was used. Without the insulating cement layer (i.e. during drilling of the cementless bone-prosthesis construct), the temperature increased to 47 °C.
CONCLUSION: Constantly applied internal cooling can avoid structural bone and soft tissue damage during drilling procedures. With a cement layer, the temperatures only increased to non-damaging levels. The results could be useful in the treatment of periprosthetic fractures with intraprosthetic implant fixation.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23775453      PMCID: PMC3779579          DOI: 10.1007/s00264-013-1964-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  19 in total

1.  Temperature changes during high-speed drilling on bone.

Authors:  S S RAFEL
Journal:  J Oral Surg Anesth Hosp Dent Serv       Date:  1962-11

2.  A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model.

Authors:  Nicky Bertollo; Hadley R M Milne; Liam P Ellis; Paul C Stephens; Ronald M Gillies; William R Walsh
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-04-01       Impact factor: 2.063

3.  Drilling of bone.

Authors:  K L Wiggins; S Malkin
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

4.  Influence of different parameters on bone heating and drilling time in implantology.

Authors:  Y Reingewirtz; S Szmukler-Moncler; B Senger
Journal:  Clin Oral Implants Res       Date:  1997-06       Impact factor: 5.977

5.  Effect of drill speed on bone temperature.

Authors:  M B Abouzgia; J M Symington
Journal:  Int J Oral Maxillofac Surg       Date:  1996-10       Impact factor: 2.789

6.  Temperature control with internally applied cooling in solid material drilling: an experimental, biomechanical study.

Authors:  Stephan Brand; Johannes Klotz; Maximilian Petri; Max Ettinger; Thomas Hassel; Christian Krettek; Thomas Goesling; Friedrich-Wilhelm Bach
Journal:  Int Orthop       Date:  2013-03-20       Impact factor: 3.075

7.  Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury.

Authors:  J Lundskog
Journal:  Scand J Plast Reconstr Surg       Date:  1972

8.  Biomechanical factors in designing screws for the Orthofix system.

Authors:  F M Lavini; L R Brivio; P Leso
Journal:  Clin Orthop Relat Res       Date:  1994-11       Impact factor: 4.176

9.  Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.

Authors:  Goran Augustin; Slavko Davila; Toma Udilljak; Tomislav Staroveski; Danko Brezak; Slaven Babic
Journal:  Int Orthop       Date:  2012-07       Impact factor: 3.075

10.  Osteosynthesis of a periprosthetic fracture of the proximal femur with the distal femur LISS system.

Authors:  Jan Robert Tarnowski; Kim Holck
Journal:  Acta Orthop Belg       Date:  2008-02       Impact factor: 0.500

View more
  2 in total

1.  Minimally invasive surgery with locking plate for periprosthetic femoral fractures: technical note.

Authors:  Matthieu Ehlinger; Benjamin Scheibling; Michel Rahme; David Brinkert; Benoit Schenck; Antonio Di Marco; Philippe Adam; François Bonnomet
Journal:  Int Orthop       Date:  2015-08-08       Impact factor: 3.075

2.  Concepts and Potential Future Developments for Treatment of Periprosthetic Proximal Femoral Fractures.

Authors:  Stephan Brand; Max Ettinger; Mohamed Omar; Nael Hawi; Christian Krettek; Maximilian Petri
Journal:  Open Orthop J       Date:  2015-08-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.