Literature DB >> 23773494

A new left atrial appendage occluder (Lifetech LAmbre Device) for stroke prevention in atrial fibrillation.

Yat-Yin Lam1.   

Abstract

Non-valvular atrial fibrillation (AF) is the commonest cardiac arrhythmia which causes ischemic stroke. Percutaneous left atrial appendage (LAA) closure is increasingly performed in AF patients with high stroke and bleeding risks. WATCHMAN and Amplatzer Cardiac Plug are the two mostly implanted devices worldwide with good clinical results. However, the need for relatively large delivery sheaths (9-14 French) and limited recapture and repositioning capabilities remains problematic for both devices. LAmbre is a new; self-expanding LAA occluder constructed from a nitinol mesh and polyester membranes. It consists of an umbrella and a cover connected by a short central waist. The device is delivered by an 8-10 French sheath and has full recapture and repositioning capabilities. This report discussed in detail the novel features andprocedural steps for LAmbre device.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23773494     DOI: 10.1016/j.carrev.2013.04.003

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  17 in total

1.  Five years of keeping a watch on the left atrial appendage-how has the WATCHMAN fared?

Authors:  Mohammad-Ali Jazayeri; Venkat Vuddanda; Valay Parikh; Madhav Lavu; Donita Atkins; Y Madhu Reddy; Jayant Nath; Dhanunjaya R Lakkireddy
Journal:  J Thorac Dis       Date:  2016-12       Impact factor: 2.895

Review 2.  Left atrial appendage exclusion for prevention of stroke in atrial fibrillation: review of minimally invasive approaches.

Authors:  Joshua D Moss
Journal:  Curr Cardiol Rep       Date:  2014-02       Impact factor: 2.931

3.  Left atrial appendage exclusion for atrial fibrillation: does the protection from stroke prevail in the long-term?

Authors:  Vaibhav R Vaidya; Roshini Asirvatham; Jason Tri; Samuel J Asirvatham
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

Review 4.  [Available transvenous occluder designs and implantation techniques].

Authors:  P Sick; T Lewalter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-10-27

Review 5.  Interventional and surgical occlusion of the left atrial appendage.

Authors:  Etem Caliskan; James L Cox; David R Holmes; Bernhard Meier; Dhanunjaya R Lakkireddy; Volkmar Falk; Sacha P Salzberg; Maximilian Y Emmert
Journal:  Nat Rev Cardiol       Date:  2017-08-10       Impact factor: 32.419

Review 6.  Percutaneous Left Atrial Appendage Ligation for Stroke Prevention in Atrial Fibrillation.

Authors:  Miguel Valderrábano; Matthew J Price
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Apr-Jun

Review 7.  The Optimal Treatment For Atrial Fibrillation In Less Developed Countries.

Authors:  Xiaohan Fan; Shu Zhang
Journal:  J Atr Fibrillation       Date:  2014-10-31

Review 8.  Left Atrial Appendage Ligation And Exclusion Technology In The Incubator.

Authors:  Faisal F Syed; Amit Noheria; Christopher V DeSimone; Samuel J Asirvatham
Journal:  J Atr Fibrillation       Date:  2015-08-31

9.  Left Atrial Appendage Closure Devices For Stroke Prevention.

Authors:  Sunil Kapur; Moussa Mansour
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

Review 10.  Approaches to Left Atrial Appendage Closure: Device Design, Performance, and Limitations.

Authors:  Amish S Dave; Miguel Valderrábano
Journal:  Methodist Debakey Cardiovasc J       Date:  2017 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.