Platelet counting with the BD Accuri(TM) C6 flow cytometer.

Andrew Masters1, Paul Harrison.   

Abstract

The Accuri™ C6 is a compact flow cytometer that uses a peristaltic pump with a laminar flow fluidic system and can measure absolute cell counts. In this study we have evaluated this method with the International Reference Method (IRM) simultaneously measured on both the Accuri™ C6 and a reference flow cytometer. After optimisation of sample labelling conditions, final dilutions and flow cytometer settings, a comparison of the absolute fluorescent platelet count with the RBC/platelet ratio on the C6 and the IRM was then performed in 144 patient samples with a full range of platelet counts (range 2-650 × 10(9)/l). The platelet/RBC ratio method determined on the Accuri™ agreed well with the IRM (R(2)=0.99, bias=2.3 (Bland Altman) and R(2)=0.96, bias=1.02 at counts <50 × 10(9)/l). The absolute platelet count also agreed well with the IRM (R(2)=0.97, bias=-0.16 and R(2)=0.91, bias=3.7 at <50 × 10(9)/l). The C6 absolute platelet count and RBC/platelet ratio methods also agreed well (R(2)=0.99, bias=-2.5 and R(2)=0.95, bias=2.71 at counts <50 × 10(9)/l). Reproducibility studies on the C6 gave CVs of <5% for the RB/platelet ratio and <12% for the absolute cell counts. The C6 also demonstrated excellent linearity on diluted samples with both volume and ratio methods (R(2)=0.99). As one might expect, the absolute platelet count is therefore slightly more inaccurate than the RBC/platelet ratio particularly at platelet counts <50 × 10(9)/l as it is likely to be more sensitive to pipetting error. The Accuri™ C6 provides a simple, rapid and reliable method for measuring platelet counts by either the RBC/platelet or direct volume methods. The direct volume method can also be used to determine platelet counts within purified platelet preparations or concentrates in the absence of RBC.

Entities:  

Mesh:

Year:  2013        PMID: 23772865     DOI: 10.3109/09537104.2013.801947

Source DB:  PubMed          Journal:  Platelets        ISSN: 0953-7104            Impact factor:   3.862


  6 in total

1.  Evaluation of an easy and affordable flow cytometer for volumetric haematopoietic stem cell counting.

Authors:  Mariagabriella Mariani; Federico Colombo; Sonny M Assennato; Cecilia Frugoni; Alessandra Cattaneo; Elena Trombetta; Paolo Rebulla; Laura Porretti
Journal:  Blood Transfus       Date:  2014-03-19       Impact factor: 3.443

2.  The use of a stably expressed FRET biosensor for determining the potency of cancer drugs.

Authors:  William P Bozza; Xu Di; Kazuyo Takeda; Leslie A Rivera Rosado; Sarah Pariser; Baolin Zhang
Journal:  PLoS One       Date:  2014-09-04       Impact factor: 3.240

3.  Polyphenolics from Albizia harveyi Exhibit Antioxidant Activities and Counteract Oxidative Damage and Ultra-Structural Changes of Cryopreserved Bull Semen.

Authors:  Mansour Sobeh; Soha A Hassan; Mohamed A El Raey; Wael A Khalil; Mahmoud A E Hassan; Michael Wink
Journal:  Molecules       Date:  2017-11-17       Impact factor: 4.411

4.  Single platelet variability governs population sensitivity and initiates intrinsic heterotypic responses.

Authors:  Maaike S A Jongen; Ben D MacArthur; Nicola A Englyst; Jonathan West
Journal:  Commun Biol       Date:  2020-06-04

5.  Droplet Microfluidics with Reagent Micromixing for Investigating Intrinsic Platelet Functionality.

Authors:  Maaike S A Jongen; Paul M Holloway; Simon I R Lane; Nicola A Englyst; Owen J T McCarty; Jonathan West
Journal:  Cell Mol Bioeng       Date:  2021-01-21       Impact factor: 2.321

6.  Comparison between the Effects of Adding Vitamins, Trace Elements, and Nanoparticles to SHOTOR Extender on the Cryopreservation of Dromedary Camel Epididymal Spermatozoa.

Authors:  Mohamed A Shahin; Wael A Khalil; Islam M Saadeldin; Ayman Abdel-Aziz Swelum; Mostafa A El-Harairy
Journal:  Animals (Basel)       Date:  2020-01-02       Impact factor: 2.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.