Literature DB >> 23770636

A rapid, accurate and robust UHPLC-MS/MS method for quantitative determination of BMS-927711, a CGRP receptor antagonist, in plasma in support of non-clinical toxicokinetic studies.

Naiyu Zheng1, Jianing Zeng, Billy Akinsanya, Adela Buzescu, Yuan-Qing Xia, Van Ly, Kevin Trouba, Qianping Peng, Anne-Françoise Aubry, Mark E Arnold.   

Abstract

BMS-927711 is a calcitonin gene-related peptide (CGRP) receptor antagonist that is being developed for the treatment of migraine. A rapid, accurate and robust assay was developed and validated for the quantitation of BMS-927711 in rat, monkey, rabbit and mouse plasma using ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). A simplified method screening strategy was utilized that included a liquid-liquid extraction (LLE) methodology and eleven LC columns (ten sub-2 μm UHPLC columns and one 2.6 μm HPLC column) for screening with emphasis on the removal of phospholipids, avoidance of metabolite interference and ruggedness of LC conditions. A stable isotope labeled [(13)C2, D4]-BMS-927711 was used as the internal standard, and 50 μL of plasma samples were used for extraction by automated LLE with methyl tert-butyl ether (MTBE) in 96-well format. Chromatographic separation was achieved with an isocratic elution and a gradient column wash on a Waters Acuity UPLC(®) BEH C18 column (2.1 mm × 50 mm, 1.7 μm) with run time of 3.7 min. Positive electrospray ionization was performed using selected reaction monitoring (SRM) with transitions of m/z 535>256 for BMS-927711 and m/z 541>256 for [(13)C2, D4]-BMS-927711. The standard curve, which ranged from 3.00 to 3000 ng/mL for BMS-927711, was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within 5.2% CV, inter-assay precision was within 5.9% CV, and the assay accuracy was within ±5.2% deviation (%Dev) of the nominal values in all the species. The stability of an N-carbamoyl glucuronide metabolite was carefully investigated, and the conversion of this metabolite to BMS-927711 was minimal and manageable without a stabilization procedure. The method was successfully applied to multiple non-clinical toxicokinetic studies in different species in support of the investigative new drug (IND) filing.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23770636     DOI: 10.1016/j.jpba.2013.05.019

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  1 in total

1.  A validated high-throughput UHPLC-MS/MS assay for accurate determination of rivaroxaban in plasma sample.

Authors:  Muzaffar Iqbal; Nasr Y Khalil; Faisal Imam; Md Khalid Anwer
Journal:  J Thromb Thrombolysis       Date:  2015-01       Impact factor: 2.300

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.