Literature DB >> 23767936

Combination of capillary isoelectric focusing in a tapered capillary with MALDI-TOF MS for rapid and reliable identification of Dickeya species from plant samples.

Marie Horká1, Jiří Salplachta, Pavel Karásek, Anna Kubesová, Jaroslav Horký, Hana Matoušková, Karel Slais, Michal Roth.   

Abstract

This study was undertaken to investigate feasibility of a combination of capillary isoelectric focusing (CIEF) in a tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for a rapid and reliable identification of bacteria taken from plant-tissue-containing samples. Eight strains representing different species of the genus Dickeya were selected on the basis of close proximity of their isoelectric points: D. chrysanthemi, D. chrysanthemi bv. parthenii, D. chrysanthemi bv. chrysanthemi, D. dadantii, D. paradisiaca, D. solani, D. diffenbachiae, and D. dianthicola. Because the Dickeya species (spp.) cannot be easily discriminated from each other when CIEF is performed in a cylindrical FS capillary (commonly used in CIEF) even if a narrow pH gradient is used, a tapered FS capillary was employed instead, which enabled satisfactory discrimination of the examined bacteria due to enhanced separation efficiency of CIEF in the tapered FS capillary. CIEF in the tapered FS capillary was also successfully used for the detection and characterization of Dickeya spp. in a plant-tissue-containing sample. Then an off-line combination of CIEF with MALDI-TOF MS was employed for rapid and reliable identification of Dickeya spp. in the plant-tissue-containing sample. It was found that the presence of plant tissue did not affect the results, making the proposed procedure very promising with respect to the fast and reliable detection and identification of bacteria in plant-tissue-containing samples.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23767936     DOI: 10.1021/ac4009176

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  1 in total

1.  Nano-etched fused-silica capillary used for on-line preconcentration and electrophoretic separation of bacteriophages from large blood sample volumes with off-line MALDI-TOF mass spectrometry identification.

Authors:  Marie Horká; Pavel Karásek; Jiří Šalplachta; Filip Růžička; Dana Štveráková; Roman Pantůček; Michal Roth
Journal:  Mikrochim Acta       Date:  2020-02-19       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.