Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin.

Dong Hyuk Shin1, Pil Cho Choi, Ji Ung Na, Jun Hwi Cho, Sang Kuk Han.   

Abstract

INTRODUCTION: Following a chemical, biological, radiation and nuclear (CBRN) incident, prompt establishment of an advanced airway is required for patients with respiratory failure within the warm zone, while wearing personal protective equipment (PPE). Previous studies reported that intubation attempts were prolonged, and incidence of esophageal intubation was increased with conventional Macintosh laryngoscope (McL), while wearing CBRN-PPE. Pentax-AWS (AWS), a recently introduced portable video laryngoscope, was compared with the McL to test its utility for tracheal intubation while wearing CBRN-PPE.
METHODS: 31 participants performed unsuited and suited intubations on an advanced life support simulator. The sequence of intubating devices and PPE wearing were randomised. Time to complete tracheal intubation (primary end point), time to see the vocal cords, overall success rate, percentage of glottic opening, dental compression and ease of intubation were measured.
RESULTS: Suited intubations required significantly longer time to complete intubation than unsuited intubations, in both McL and AWS (22.2 vs 26.4 s, 14.2 vs 18.2 s, respectively). However, suited AWS intubations required shorter time to complete tracheal intubation than unsuited McL intubations (18.2 vs 22.2 s). In secondary outcomes, moreover, suited intubations using the AWS compared favourably with unsuited intubations using the McL.
CONCLUSIONS: Although the CBRN-PPE adversely affected time required to complete tracheal intubation with the AWS, suited intubations using the AWS were even superior to unsuited intubations using the McL. The AWS should be a promising device to perform tracheal intubation while wearing the CBRN-PPE.

Entities:  

Keywords:  CBRN; airway; intubation; manikin; resuscitation; toxicology; video laryngoscopy

Mesh:

Substances:

Year:  2013        PMID: 23765764     DOI: 10.1136/emermed-2012-201463

Source DB:  PubMed          Journal:  Emerg Med J        ISSN: 1472-0205            Impact factor:   2.740


  4 in total

Review 1.  Randomized controlled trials of simulation-based interventions in Emergency Medicine: a methodological review.

Authors:  Anthony Chauvin; Jennifer Truchot; Aida Bafeta; Dominique Pateron; Patrick Plaisance; Youri Yordanov
Journal:  Intern Emerg Med       Date:  2017-11-16       Impact factor: 3.397

2.  Systematic review of simulated airway management whilst wearing personal protective equipment.

Authors:  Filippo Sanfilippo; Stefano Tigano; Gaetano J Palumbo; Marinella Astuto; Paolo Murabito
Journal:  Br J Anaesth       Date:  2020-06-13       Impact factor: 9.166

3.  Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study.

Authors:  H Schröder; N Zoremba; R Rossaint; K Deusser; C Stoppe; M Coburn; A Rieg; G Schälte
Journal:  BMJ Open       Date:  2016-03-15       Impact factor: 2.692

4.  Personal protective equipment, airway management, and systematic reviews. Comment on Br J Anaesth 2020; 125: e301-5.

Authors:  Massimiliano Sorbello; Kariem El-Boghdadly; Jan Schumacher; Imran Ahmad
Journal:  Br J Anaesth       Date:  2020-06-30       Impact factor: 9.166

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.