Literature DB >> 23764967

Comparison of spectral-domain and time-domain optical coherence tomography in the detection of neovascular age-related macular degeneration activity.

James C Major1, Charles C Wykoff, Angeline F Mariani, Eric Chen, Daniel E Croft, David M Brown.   

Abstract

PURPOSE: To compare the sensitivity of commonly used time-domain (TD-OCT) and spectral-domain optical coherence tomography platforms and scanning modalities in the management of neovascular age-related macular degeneration in a population with a high prevalence of exudative disease activity.
METHODS: Fifty consecutive patients within the prospective SAVE (Super-dose Anti-Vascular Endothelial growth factor) trial, which analyzed the utility of 2.0 mg intravitreal ranibizumab for the treatment of recalcitrant neovascular age-related macular degeneration, were enrolled in a comparison trial of 3 different optical coherence tomography (OCT) platforms. Stratus TD-OCT radial scan (Carl Zeiss Meditec, Inc) was compared with 3 Heidelberg Spectralis Heidelberg Retinal Angiograph+OCT (Heidelberg Engineering) acquisition settings (radial, 7-line raster, volumetric) and 2 Cirrus high definition (HD)-OCT (Carl Zeiss Meditec, Inc) acquisition settings (5-line raster, volumetric).
RESULTS: Using every imaging platform and acquisition setting, evidence of exudative disease activity was positively identified in 163 of 191 patient visits (85.3%). Intraretinal cysts were identified in 83 of 191 visits (43.5%), and subretinal fluid was identified in 116 of 191 visits (60.7%). Of these positive visits, the Stratus TD-OCT radial scanning technology demonstrated a significantly lower rate of detection (71.8%) when compared with the Spectralis HRA+OCT spectral domain scanning modalities (radial 87.1%, P < 0.001; 7-line raster 92.0%, P < 0.001; volumetric 94.5%, P < 0.001) or the Cirrus HD-OCT spectral domain scanning modalities (5-line raster 81.6%, P = 0.001; volumetric 92.0%, P < 0.001). Intraretinal cysts and subretinal fluid were identified in 83 visits (43.5%) and 116 visits (60.7%), respectively, with 36 eyes (18.8%) having fluid in both locations. No individual imaging modality demonstrated a diagnostic advantage for detecting subretinal fluid versus intraretinal cysts (e.g., Cirrus volume detected 86.7% of intraretinal cysts and 88.8% of subretinal fluid, P = 0.33).
CONCLUSION: In this neovascular age-related macular degeneration patient population, spectral-domain ocular coherence tomography was a superior diagnostic tool when compared with TD-OCT, with each spectral domain platform and acquisition setting identifying significantly more exudative disease activity. The two spectral domain platforms (Cirrus and Spectralis) were not directly compared because identical image acquisition parameters were not used. No individual imaging modality demonstrated a diagnostic advantage for detecting subretinal fluid versus intraretinal cysts.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 23764967     DOI: 10.1097/IAE.0b013e3182965743

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  6 in total

1.  COMPARISON OF SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY SCAN PATTERNS AND CLINICAL REVIEW STRATEGIES IN NEOVASCULAR AGE-RELATED MACULAR DEGENERATION.

Authors:  Robert J Courtney; Jedediah I McClintic; Justis P Ehlers
Journal:  Retina       Date:  2015-07       Impact factor: 4.256

Review 2.  An evidence-based approach to the routine use of optical coherence tomography.

Authors:  Angelica Ly; Jack Phu; Paula Katalinic; Michael Kalloniatis
Journal:  Clin Exp Optom       Date:  2018-12-17       Impact factor: 2.742

3.  A Retrospective Analysis of the Effect of Subretinal Hyper-Reflective Material and Other Morphological Features of Neovascular Age-Related Macular Degeneration on Visual Acuity Outcomes in Eyes Treated with Intravitreal Aflibercept over One Year.

Authors:  King Fai Calvin Leung; Susan M Downes; Victor Chong
Journal:  Vision (Basel)       Date:  2018-01-31

4.  Multimodal imaging and diagnosis of myopic choroidal neovascularization in Caucasians.

Authors:  Paolo Milani; Amedeo Massacesi; Stefania Moschini; Marco Setaccioli; Ennio Bulone; Gemma Tremolada; Stefano Ciaccia; Elena Mantovani; Daniela Morale; Fulvio Bergamini
Journal:  Clin Ophthalmol       Date:  2016-09-12

5.  Relationship between macular thickness measurement and signal strength using Stratus optical coherence tomography.

Authors:  Ori Segal; Yinon Shapira; Assaf Gershoni; Igor Vainer; Arie Y Nemet; Noa Geffen; Michael Mimouni
Journal:  Clin Ophthalmol       Date:  2016-11-11

6.  OPTICAL COHERENCE TOMOGRAPHY, FLUORESCEIN ANGIOGRAPHY, AND DIAGNOSIS OF CHOROIDAL NEOVASCULARIZATION IN AGE-RELATED MACULAR DEGENERATION.

Authors:  Vincent Gualino; Ramin Tadayoni; Salomon Yves Cohen; Ali Erginay; Franck Fajnkuchen; Belkacem Haouchine; Valérie Krivosic; Gabriel Quentel; Eric Vicaut; Alain Gaudric
Journal:  Retina       Date:  2019-09       Impact factor: 4.256

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.