Literature DB >> 23764744

Performance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.

Hee-Won Moon1, Sun Hwa Lee2, Hae-Sun Chung3, Miae Lee3, Kyungwon Lee4.   

Abstract

We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS correctly identified the species of 97.2 % of the staphylococci (95.9 % of coagulase-negative staphylococci), 97.8 % of the streptococci, and 100 % of the enterococci. For the identification of Gram-positive cocci isolates, the overall concordance rate between conventional identification and the Vitek MS was 94.5 %. The Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) system can be a reliable and rapid method for the identification of most relevant Gram-positive cocci. In addition, expanding the database of the Vitek MS, especially for coagulase-negative staphylococci, is needed to enhance the performance of the Vitek MS.

Mesh:

Substances:

Year:  2013        PMID: 23764744     DOI: 10.1099/jmm.0.062950-0

Source DB:  PubMed          Journal:  J Med Microbiol        ISSN: 0022-2615            Impact factor:   2.472


  11 in total

1.  The ongoing revolution of MALDI-TOF mass spectrometry for microbiology reaches tropical Africa.

Authors:  Bécaye Fall; Cheikh Ibrahima Lo; Bissoume Samb-Ba; Nadine Perrot; Silman Diawara; Mamadou Wague Gueye; Kowry Sow; Maxence Aubadie-Ladrix; Oleg Mediannikov; Cheikh Sokhna; Yaya Diemé; Sonia Chatellier; Boubacar Wade; Didier Raoult; Florence Fenollar
Journal:  Am J Trop Med Hyg       Date:  2015-01-19       Impact factor: 2.345

2.  The changing culture of the microbiology laboratory.

Authors:  Kevin B Laupland; Louis Valiquette
Journal:  Can J Infect Dis Med Microbiol       Date:  2013       Impact factor: 2.471

Review 3.  Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review.

Authors:  W-T Fan; T-T Qin; R-R Bi; H-Q Kang; P Ma; B Gu
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-01-23       Impact factor: 3.267

4.  Direct Identification of Urinary Tract Pathogens From Urine Samples Using the Vitek MS System Based on Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

Authors:  Yeongsic Kim; Kang Gyun Park; Kyungwon Lee; Yeon-Joon Park
Journal:  Ann Lab Med       Date:  2015-05-21       Impact factor: 3.464

5.  Clinical and microbiological characteristics of six Staphylococcus pettenkoferi isolates from blood samples.

Authors:  Sholhui Park; Hae-Sun Chung; Miae Lee
Journal:  Ann Lab Med       Date:  2015-02-12       Impact factor: 3.464

6.  Identification of viridans streptococci With Matrix-Assisted Laser Desorption & Ionization Time-of-flight Mass Spectrometry by an In-house Method and a Commercially Available System.

Authors:  Catalina Suzana Stingu; Klaus Eschrich; Juliane Thiel; Toralf Borgmann; Reiner Schaumann; Arne C Rodloff
Journal:  Ann Lab Med       Date:  2017-09       Impact factor: 3.464

7.  Head-to-head comparison of Microflex LT and Vitek MS systems for routine identification of microorganisms by MALDI-TOF mass spectrometry in Chile.

Authors:  Lorena Porte; Patricia García; Stephanie Braun; María Teresa Ulloa; Mónica Lafourcade; Alisson Montaña; Carolina Miranda; Gerardo Acosta-Jamett; Thomas Weitzel
Journal:  PLoS One       Date:  2017-05-18       Impact factor: 3.240

8.  Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk.

Authors:  Tsi-Shu Huang; Susan Shin-Jung Lee; Chia-Chien Lee; Chiu-Yen Chen; Fang-Chen Chen; Bao-Chen Chen; Cheng Len Sy; Kuan-Sheng Wu
Journal:  PLoS One       Date:  2017-06-13       Impact factor: 3.240

9.  Evaluation of matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) for the Identification of Group B Streptococcus.

Authors:  Ka-Ning To; Emma Cornwell; Roger Daniel; Sweenie Goonesekera; Elita Jauneikaite; Victoria Chalker; Kirsty Le Doare
Journal:  BMC Res Notes       Date:  2019-02-14

10.  Antibiotic sensitivities of coagulase-negative staphylococci and Staphylococcus aureus in hip and knee periprosthetic joint infections: does this differ if patients meet the International Consensus Meeting Criteria?

Authors:  Elena De Vecchi; David A George; Carlo L Romanò; Fabrizio E Pregliasco; Roberto Mattina; Lorenzo Drago
Journal:  Infect Drug Resist       Date:  2018-04-13       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.