Literature DB >> 23763591

In vivo assessment of bone healing following Piezotome® ultrasonic instrumentation.

Jonathan Reside1, Eric Everett, Ricardo Padilla, Roger Arce, Patricia Miguez, Nadine Brodala, Ingeborg De Kok, Salvador Nares.   

Abstract

PURPOSE: This pilot study evaluated the molecular, histologic, and radiographic healing of bone to instrumentation with piezoelectric or high speed rotary (R) devices over a 3-week healing period.
MATERIAL AND METHODS: Fourteen Sprague-Dawley rats (Charles River Laboratories International, Inc., Wilmington, MA, USA) underwent bilateral tibial osteotomies prepared in a randomized split-leg design using Piezotome® (P1) (Satelec Acteon, Merignac, France), Piezotome 2® (P2) (Satelec Acteon), High-speed R instrumentation, or sham surgery (S). At 1 week, an osteogenesis array was used to evaluate differences in gene expression while quantitative analysis assessed percentage bone fill (PBF) and bone mineral density (BMD) in the defect, peripheral, and distant regions at 3 weeks. Qualitative histologic evaluation of healing osteotomies was also performed at 3 weeks.
RESULTS: At 1 week, expression of 11 and 18 genes involved in bone healing was significantly (p < .05) lower following P1 and P2 instrumentation, respectively, relative to S whereas 16 and 4 genes were lower relative to R. No differences in PBF or BMD were detected between groups within the osteotomy defect. However, significant differences in PBF (p = .020) and BMD (p = .008) were noted along the peripheral region between P2 and R groups, being R the group with the lowest values. Histologically, smooth osteotomy margins were present following instrumentation using P1 or P2 relative to R.
CONCLUSIONS: Piezoelectric instrumentation favors preservation of bone adjacent to osteotomies while variations in gene expression suggest differences in healing rates due to surgical modality. Bone instrumented by piezoelectric surgery appears less detrimental to bone healing than high-speed R device.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  Piezoelectric surgery; Piezotome; gene expression; histology; microCT

Mesh:

Year:  2013        PMID: 23763591     DOI: 10.1111/cid.12094

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  Bone microRNA-21 as surgical stress parameter is associated with third molar postoperative discomfort.

Authors:  Milan Vucetic; Jelena Roganovic; Martin Freilich; David Shafer; Marija Milic; Ljiljana DJukic; Nina Petrovic; Evgenija Markovic; Aleksa Markovic; Bozidar Brkovic
Journal:  Clin Oral Investig       Date:  2020-06-04       Impact factor: 3.573

2.  Biomechanical Stability of Dental Implants in Augmented Maxillary Sites: Results of a Randomized Clinical Study with Four Different Biomaterials and PRF and a Biological View on Guided Bone Regeneration.

Authors:  Troedhan Angelo; Wainwright Marcel; Kurrek Andreas; Schlichting Izabela
Journal:  Biomed Res Int       Date:  2015-04-12       Impact factor: 3.411

  2 in total