Literature DB >> 23761545

Additional gastroduodenal stent placement: retrospective evaluation of 68 consecutive patients with malignant gastroduodenal obstruction.

Min Kyoung Kang1, Ho-Young Song, Jong Woo Kim, Jin Hyoung Kim, Jung-Hoon Park, Han Kyu Na, Jong Jin Lee, Se Jin Oh.   

Abstract

BACKGROUND: Self-expandable metallic stent placement is widely used to manage malignant gastroduodenal obstructions. However, the techniques and effectiveness of additional gastroduodenal stent placement have not been evaluated until now.
PURPOSE: To evaluate the technical feasibility, clinical effectiveness, and complications of additional gastroduodenal stent placement in patients with recurrent obstructive symptoms after primary gastroduodenal stenting.
MATERIAL AND METHODS: We retrospectively analyzed data from 68 consecutive patients who had additional gastroduodenal stents placed for recurrent obstruction. Clinical effectiveness was assessed using technical and clinical success rates, gastric outlet obstruction score improvement after primary and additional stent placement, and complications.
RESULTS: Additional stent placement was technically successful in 66 of the 68 patients (97%) and symptomatic improvement was achieved in 58 (85%). The gastric outlet obstruction score improved after primary stent placement (0.3 to 1.4) and additional stent placement (0.2 to 1.4). Complications occurred in 12 of 68 patients (18%) and were caused by tumor overgrowth (n = 7), stent collapse (n = 2), food impaction (n = 1), jaundice (n = 1), and duodenal perforation (n = 1).
CONCLUSION: Additional gastroduodenal stent placement is technically feasible and clinically effective for patients with recurrent gastric outlet obstruction after stent placement.

Entities:  

Keywords:  Malignant gastroduodenal obstruction; additional stent placement; self-expandable metallic stent

Mesh:

Year:  2013        PMID: 23761545     DOI: 10.1177/0284185113485500

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Clinical outcomes of re-stenting in patients with stent malfunction in malignant gastric outlet obstruction.

Authors:  Eun Hyo Jin; Sang Gyun Kim; Ji Yeon Seo; Jong Pil Im; Joo Sung Kim; Hyun Chae Jung
Journal:  Surg Endosc       Date:  2015-07-03       Impact factor: 4.584

2.  Covered Metal Stent after Dysfunction of Uncovered Stents for Palliation of Gastrointestinal Malignant Obstruction.

Authors:  Marta Patita; Rui Castro; Diogo Libânio; Rui Pedro Bastos; Rui Silva; Mário Dinis-Ribeiro; Pedro Pimentel-Nunes
Journal:  GE Port J Gastroenterol       Date:  2020-05-13

3.  Clinical outcomes after multiple self-expandable metallic stent placement using stent-in-stent technique for malignant gastric outlet obstruction.

Authors:  Jin Won Mo; Young Min Kim; Jie-Hyun Kim; Seung Yong Shin; Young Hoon Youn; Hyojin Park
Journal:  Medicine (Baltimore)       Date:  2020-05-22       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.