OBJECTIVE: The purpose of this study was to evaluate the suitability of rehabilitative ultrasound imaging for quantification of medial gastrocnemius muscle in poststroke patients. PARTICIPANTS: Thirty stroke patients (15 men and 15 women; age 64·7 ± 5·66 years; stroke duration 437·40 ± 168·24 days) participated in this study. METHODS: Real-time B-mode ultrasonography with a 7·5-MHz linear transducer was used to measure pennation angle and muscle thickness of the medial gastrocnemius muscles with ankle joint 90° and maximal plantar flexion. Two examiners acquired images from all participants during three separate testing sessions. After the first measurement was performed, the second measurement was performed one hour later, and the third measurement was performed 1 week later. Intraclass correlation coefficients (ICCs(3,1) ) were used for estimation of reliability. RESULTS: The ICC (95% CI) for all intra-examiner reliability was good to very good, ranging from 0·69 to 0·99 (0·51-0·99), and the ICC for all interexaminer reliability was good to very good, ranging from 0·70 to 0·99 (0·46-0·99). CONCLUSION: In this study, the intra- and interexaminer reliability of the pennation angle and muscle thickness measurements of the medial gastrocnemius muscle was good to very good. Therefore, we suggest that the pennation angle and muscle thickness measurements of the medial gastrocnemius muscle obtained from rehabilitative ultrasound imaging would be useful for clinical assessment in poststroke patients.
OBJECTIVE: The purpose of this study was to evaluate the suitability of rehabilitative ultrasound imaging for quantification of medial gastrocnemius muscle in poststroke patients. PARTICIPANTS: Thirty strokepatients (15 men and 15 women; age 64·7 ± 5·66 years; stroke duration 437·40 ± 168·24 days) participated in this study. METHODS: Real-time B-mode ultrasonography with a 7·5-MHz linear transducer was used to measure pennation angle and muscle thickness of the medial gastrocnemius muscles with ankle joint 90° and maximal plantar flexion. Two examiners acquired images from all participants during three separate testing sessions. After the first measurement was performed, the second measurement was performed one hour later, and the third measurement was performed 1 week later. Intraclass correlation coefficients (ICCs(3,1) ) were used for estimation of reliability. RESULTS: The ICC (95% CI) for all intra-examiner reliability was good to very good, ranging from 0·69 to 0·99 (0·51-0·99), and the ICC for all interexaminer reliability was good to very good, ranging from 0·70 to 0·99 (0·46-0·99). CONCLUSION: In this study, the intra- and interexaminer reliability of the pennation angle and muscle thickness measurements of the medial gastrocnemius muscle was good to very good. Therefore, we suggest that the pennation angle and muscle thickness measurements of the medial gastrocnemius muscle obtained from rehabilitative ultrasound imaging would be useful for clinical assessment in poststroke patients.
Authors: Willemke Nijholt; Aldo Scafoglieri; Harriët Jager-Wittenaar; Johannes S M Hobbelen; Cees P van der Schans Journal: J Cachexia Sarcopenia Muscle Date: 2017-07-12 Impact factor: 12.910
Authors: Cesar Calvo-Lobo; Ana Isabel Useros-Olmo; Jaime Almazán-Polo; Miriam Martín-Sevilla; Carlos Romero-Morales; Irene Sanz-Corbalán; David Rodríguez-Sanz; Daniel López-López Journal: Int J Environ Res Public Health Date: 2018-11-11 Impact factor: 3.390
Authors: Cesar Calvo-Lobo; Ana Isabel Useros-Olmo; Jaime Almazán-Polo; Ricardo Becerro-de-Bengoa-Vallejo; Marta Elena Losa-Iglesias; Patricia Palomo-López; David Rodríguez-Sanz; Daniel López-López Journal: Int J Med Sci Date: 2018-06-04 Impact factor: 3.738