Literature DB >> 23756698

Transcatheter aortic valve implantation for patients with severe bicuspid aortic valve stenosis.

Kentaro Hayashida1, Erik Bouvier, Thierry Lefèvre, Bernard Chevalier, Thomas Hovasse, Mauro Romano, Philippe Garot, Yusuke Watanabe, Arnaud Farge, Patrick Donzeau-Gouge, Bertrand Cormier, Marie-Claude Morice.   

Abstract

BACKGROUND: Bicuspid aortic valve (BAV) is regarded as a relative contraindication to transcatheter aortic valve implantation attributable to the risk of uneven expansion of the bioprosthesis. The purpose of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation in patients with BAV. METHODS AND
RESULTS: Of 470 patients included in our prospective transcatheter aortic valve implantation database (October 2006-January 2012), 229 consecutive patients undergoing both echocardiography and multidetector computed tomography were analyzed. We compared clinical outcomes in patients with vs patients without BAV. In this series of 229 patients, BAV was detected by multidetector computed tomography in 21 patients (9.2%). BAV was identified by transthoracic and transoesophageal echocardiography in only 9 of these 21 patients. Patients were 83.1±6.6 years old, and European system for cardiac operative risk evaluation score was 20.0%±11.4%. The BAV group was similar to the non-BAV group except for diabetes mellitus (4.8% vs 24.0%; P=0.05). The aortic annulus diameter in BAV patients was not significantly larger by multidetector computed tomography (24.7±3.0 vs 23.7±1.9 mm; P=0.07). The CoreValve was used more frequently in the BAV group (47.6% vs 16.3%; P=0.002). There was no significant difference in device success (100% vs 92.8%; P=0.37), risk of annulus rupture (0% vs 1.4%; P=1.00), or valve migration (0% vs 1.4%; P=1.00) in BAV patients compared with non-BAV patients. Post-procedural mean gradient (10.0±3.4 vs 9.7±4.1 mm Hg; P=0.58), aortic regurgitation ≥2 of 4 (19.0% vs 14.9%; P=0.54), 30-day mortality (4.8% vs 8.2%; P=1.00), and 30-day combined safety end point (14.3% vs 13.5%; P=1.00) were also similar in both groups.
CONCLUSIONS: In selected BAV patients, transcatheter aortic valve implantation may be associated with low complication rate, efficacy, and acceptable outcomes similar to those in non-BAV patients.

Entities:  

Keywords:  aortic stenosis; bicuspid aortic valve; computed tomography; echocardiography; transcatheter aortic valve implantation

Mesh:

Year:  2013        PMID: 23756698     DOI: 10.1161/CIRCINTERVENTIONS.112.000084

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  36 in total

1.  Transcatheter Advances in the Treatment of Adult and Congenital Valvular Heart Disease.

Authors:  Jayendrakumar S Patel; Samir R Kapadia; Lourdes Prieto; E Murat Tuzcu; Amar Krishnaswamy
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-11

2.  Valvular disease: TAVI safe and effective for patients with a bicuspid aortic valve.

Authors:  Gregory B Lim
Journal:  Nat Rev Cardiol       Date:  2013-07-02       Impact factor: 32.419

Review 3.  Transcatheter aortic valve implantation in bicuspid anatomy.

Authors:  Zhen-Gang Zhao; Hasan Jilaihawi; Yuan Feng; Mao Chen
Journal:  Nat Rev Cardiol       Date:  2014-10-14       Impact factor: 32.419

Review 4.  Current topics on bicuspid aortic valve: clinical aspects and surgical management.

Authors:  Hiroshi Furukawa; Kazuo Tanemoto
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-06-19       Impact factor: 1.520

5.  Transcatheter aortic valve implantation for Chinese patients with bicuspid aortic valve.

Authors:  Yu-guo Weng
Journal:  J Zhejiang Univ Sci B       Date:  2015-04       Impact factor: 3.066

Review 6.  Diagnosis and Outcomes of Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Stenosis.

Authors:  Sung-Han Yoon; Yoshio Maeno; Hiroyuki Kawamori; Masaki Miyasaka; Takahiro Nomura; Tomoki Ochiai; Shadi Nemanpour; Matthias Raschpichler; Rahul Sharma; Tarun Chakravarty; Raj Makkar
Journal:  Interv Cardiol       Date:  2018-05

7.  Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.

Authors:  Yuan Wang; Moyang Wang; Guanyuan Song; Wei Wang; Bin Lv; Hao Wang; Yongjian Wu
Journal:  Eur Radiol       Date:  2018-06-20       Impact factor: 5.315

8.  Simultaneous transcatheter aortic valve implantation and endovascular aneurysm repair in a patient with very severe aortic stenosis with abdominal aortic aneurysm.

Authors:  Yu Sato; Yu Horiuchi; Kazuyuki Yahagi; Taishi Okuno; Takayoshi Kusuhara; Motoi Yokozuka; Sumio Miura; Takeshi Taketani; Kengo Tanabe
Journal:  J Cardiol Cases       Date:  2018-01-10

Review 9.  The role of echocardiography in transcatheter aortic valve implantation.

Authors:  Toshinari Onishi; Kaoruko Sengoku; Yasuhiro Ichibori; Isamu Mizote; Koichi Maeda; Toru Kuratani; Yoshiki Sawa; Yasushi Sakata
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

10.  Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage.

Authors:  Karin Lavon; Gil Marom; Matteo Bianchi; Rotem Halevi; Ashraf Hamdan; Adi Morany; Ehud Raanani; Danny Bluestein; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2019-08-01       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.