Quality assurance of rapid arc treatments: performances and pre-clinical verifications of a planar detector (MapCHECK2).

G Rinaldin1, L Perna2, G Agnello2, G Pallazzi2, G M Cattaneo2, C Fiorino2, R Calandrino2.   

Abstract

The purpose of this study is to evaluate the use of MapCHECK2 in a patient-specific quality assurance (QA) procedure for Rapid Arc (RA) radiotherapy and to obtain reference values of gamma index (γ) for different irradiation geometries. Dose distributions of 386 patients, optimized with Eclipse treatment planning system for RA on Varian Clinac 2300IX were exported and measured with MapCHECK2 detector array inserted in a MapPHAN dedicated phantom. Gamma index analysis was used to evaluate differences between calculated and delivered doses; collected data were analysed on the basis of complexity of plans and type of disease. Angular dependence and dose drift of detectors were estimated. The overall mean passing rate (percentage of points with γ < 1) was equal to 97.0% ± 3.1%; plan-specific evaluation of %γ < 1 showed significant differences among different treatment protocols (pancreas 98.6% ± 1.5%, prostate 96.6% ± 2.8% and rectum 92.8% ± 5.7%). MapCHECK2 demonstrated a strong angular dependence over a restricted range of angles (90° ± 5° and 270° ± 5°); this condition affected the result of pre-treatment QA only for plans with intense lateral fluence. The drift of diode array response due to the accumulated dose was found to be comparable with the manufacturer's declaration (0.5% per 1000 Gy). MapCHECK2 proved to be a useful and accurate tool in the process of patient-specific QA for RA treatment. Excluding the irradiation geometries with a high contribution of lateral fluence, the mean percentage of cases with γ-index > 95% equal to 90.3% was obtained instead of 81.7% including all plans.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  MapCHECK; QA; Rapid arc; Rotational IMRT

Mesh:

Year:  2013        PMID: 23751395     DOI: 10.1016/j.ejmp.2013.05.004

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  9 in total

1.  Comparison of Dosimetric Performance among Commercial Quality Assurance Systems for Verifying Pretreatment Plans of Stereotactic Body Radiotherapy Using Flattening-Filter-Free Beams.

Authors:  Jin Beom Chung; Sang Won Kang; Keun Yong Eom; Changhoon Song; Kyoung Sik Choi; Tae Suk Suh
Journal:  J Korean Med Sci       Date:  2016-11       Impact factor: 2.153

2.  Anatomy-based, patient-specific VMAT QA using EPID or MLC log files.

Authors:  Dewayne L Defoor; Luis A Vazquez-Quino; Panayiotis Mavroidis; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

3.  Evaluating the Impact of Various Parameters on the Gamma Index Values of 2D Diode Array in IMRT Verification.

Authors:  Keyvan Jabbari; Fakhereh Pashaei; Mohammad R Ay; Alireza Amouheidari; Mohammad B Tavakoli
Journal:  J Med Signals Sens       Date:  2018 Jan-Mar

4.  Appropriate reduction of the fragmentation level of subfield sequences to improve the accuracy of field delivery in IMRT for nasopharyngeal carcinoma.

Authors:  Yanze Sun; Gang Zhou; Yaqun Zhu; Li Zou; Ye Tian
Journal:  Br J Radiol       Date:  2020-02-12       Impact factor: 3.039

5.  Replacing Manual Planning of Whole Breast Irradiation With Knowledge-Based Automatic Optimization by Virtual Tangential-Fields Arc Therapy.

Authors:  Roberta Castriconi; Pier Giorgio Esposito; Alessia Tudda; Paola Mangili; Sara Broggi; Andrei Fodor; Chiara L Deantoni; Barbara Longobardi; Marcella Pasetti; Lucia Perna; Antonella Del Vecchio; Nadia Gisella Di Muzio; Claudio Fiorino
Journal:  Front Oncol       Date:  2021-08-24       Impact factor: 6.244

6.  Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system.

Authors:  Imad Ali; Nesreen Alsbou; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2021-11-25       Impact factor: 2.102

7.  Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT).

Authors:  Zhengzheng Xu; Iris Z Wang; Lalith K Kumaraswamy; Matthew B Podgorsak
Journal:  Radiol Oncol       Date:  2016-02-16       Impact factor: 2.991

8.  Interplay effect of angular dependence and calibration field size of MapCHECK 2 on RapidArc quality assurance.

Authors:  Hosang Jin; Vance P Keeling; Daniel A Johnson; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

9.  The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates.

Authors:  Daniel W Bailey; Jason D Spaans; Lalith K Kumaraswamy; Matthew B Podgorsak
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.