Variation of the impact duration during the in vitro insertion of acetabular cup implants.

Vincent Mathieu1, Adrien Michel, Charles-Henri Flouzat Lachaniette, Alexandre Poignard, Philippe Hernigou, Jérome Allain, Guillaume Haïat.   

Abstract

The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples taken from bovine femurs were prepared ex vivo for the insertion of an acetabular cup implant, following the surgical procedure used in the clinic. For each bone sample, ten impacts were applied using reproducible mass falls (3.5 kg) in order to insert the AC implant. Each impact duration was recorded using a wide bandwidth force sensor. For all bone samples, the impact duration was shown to first decrease as a function of the impact number, then reaching a stationary value equal in average to 4.2±0.7 ms after an average number of 4.1±1.7 impacts. The impact duration may be related to variations of the bone-implant interface contact rigidity because of an increase the amount of bone tissue in contact with the AC implant. Measurements of impact duration have a good potentiality for clinical application to assist the surgeon during the insertion of the AC implant, providing valuable information on the bone-implant interface contact properties.
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Acetabular cup implant; Impact; Primary stability

Mesh:

Year:  2013        PMID: 23746910     DOI: 10.1016/j.medengphy.2013.04.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

2.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

3.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

Review 4.  What every surgeon should know about Ceramic-on-Ceramic bearings in young patients.

Authors:  Philippe Hernigou; François Roubineau; Charlie Bouthors; Charles-Henri Flouzat-Lachaniette
Journal:  EFORT Open Rev       Date:  2017-03-13

5.  A parametric numerical analysis of femoral stem impaction.

Authors:  Nicholas E Bishop; Phil Wright; Martin Preutenborbeck
Journal:  PLoS One       Date:  2022-05-20       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.