Literature DB >> 23746403

Disposable amperometric magnetoimmunosensor for the sensitive detection of the cardiac biomarker amino-terminal pro-B-type natriuretic peptide in human serum.

Berta Esteban-Fernández de Ávila1, Vanessa Escamilla-Gómez, Susana Campuzano, María Pedrero, José M Pingarrón.   

Abstract

A novel amperometric magnetoimmunosensor using an indirect competitive format is developed for the sensitive detection of the amino-terminal pro-B-type natriuretic peptide (NT-proBNP). The immunosensor design involves the covalent immobilization of the antigen onto carboxylic-modified magnetic beads (HOOC-MBs) activated with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) and N-hydroxysulfosuccinimide (sulfo-NHS), and further incubation in a mixture solution containing variable concentrations of the antigen and a fixed concentration of an HRP-labeled detection antibody. Accordingly, the target NT-proBNP in the sample and that immobilized on the MBs compete for binding to a fixed amount of the specific HRP-labeled secondary antibody. The immunoconjugate-bearing MBs are captured by a magnet placed under the surface of a disposable gold screen-printed electrode (Au/SPE). The amperometric responses measured at -0.10 V (vs. a Ag pseudo-reference electrode), upon addition of 3,3',5,5'-tetramethylbenzidine (TMB) as electron transfer mediator and H2O2 as the enzyme substrate, are used to monitor the affinity reaction. The developed magnetoimmunosensor provides attractive analytical characteristics in 10-times diluted human serum samples, exhibiting a linear range of clinical usefulness (0.12-42.9 ng mL(-1)) and a detection limit of 0.02 ng mL(-1), which can be used in clinical diagnosis of chronic heart failure in the elderly and for classifying patients at risk of death after heart transplantation. The magnetoimmunosensor was successfully applied to the analysis of spiked human serum samples.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23746403     DOI: 10.1016/j.aca.2013.04.039

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

Review 1.  Critical overview on the application of sensors and biosensors for clinical analysis.

Authors:  Celine I L Justino; Armando C Duarte; Teresa A P Rocha-Santos
Journal:  Trends Analyt Chem       Date:  2016-04-08       Impact factor: 12.296

2.  Electrochemical Detection of NT-proBNP Using a Metalloimmunoassay on a Paper Electrode Platform.

Authors:  Nicole E Pollok; Charlie Rabin; Charuksha T Walgama; Leilani Smith; Ian Richards; Richard M Crooks
Journal:  ACS Sens       Date:  2020-03-10       Impact factor: 7.711

Review 3.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

Review 4.  Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2016-09-25       Impact factor: 3.576

5.  Ultra-Sensitive NT-proBNP Quantification for Early Detection of Risk Factors Leading to Heart Failure.

Authors:  Keum-Soo Song; Satish Balasaheb Nimse; Mukesh Digambar Sonawane; Shrikant Dashrath Warkad; Taisun Kim
Journal:  Sensors (Basel)       Date:  2017-09-14       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.