Literature DB >> 23745988

Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning.

Jun Yuan Li1, Edmond Ho Nang Pow, Li Wu Zheng, Li Ma, Dora Lai Wan Kwong, Lim Kwong Cheung.   

Abstract

OBJECTIVES: To investigate the impact of cover screw, resin embedment, and implant angulation on artifact of microcomputed tomography (micro-CT) scanning for implant.
MATERIALS AND METHODS: A total of twelve implants were randomly divided into 4 groups: (i) implant only; (ii) implant with cover screw; (iii) implant with resin embedment; and (iv) implants with cover screw and resin embedment. Implants angulation at 0°, 45°, and 90° were scanned by micro-CT. Images were assessed, and the ratio of artifact volume to total volume (AV/TV) was calculated. A multiple regression analysis in stepwise model was used to determine the significance of different factors. One-way ANOVA was performed to identify which combination of factors could minimize the artifact.
RESULTS: In the regression analysis, implant angulation was identified as the best predictor for artifact among the factors (P < 0.001). Resin embedment also had significant effect on artifact volume (P = 0.028), while cover screw had not (P > 0.05). Non-embedded implants with the axis parallel to X-ray source of micro-CT produced minimal artifact.
CONCLUSIONS: Implant angulation and resin embedment affected the artifact volume of micro-CT scanning for implant, while cover screw did not.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  CT Imaging; artifact; dental implant; micro-CT; radiology

Mesh:

Substances:

Year:  2013        PMID: 23745988     DOI: 10.1111/clr.12200

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment.

Authors:  Yanhua Lan; Xiaoyuan Huang; Mingxing Fan; Huazhen Yu; Zhijian Xie; Yiqun Zhou
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.606

Review 2.  A multiscale analytical approach to evaluate osseointegration.

Authors:  Anders Palmquist
Journal:  J Mater Sci Mater Med       Date:  2018-05-07       Impact factor: 3.896

3.  Comparison of three-dimensional digital analyses and two-dimensional histomorphometric analyses of the bone-implant interface.

Authors:  Jeong-Min Hong; Ung-Gyu Kim; In-Sung Luke Yeo
Journal:  PLoS One       Date:  2022-10-14       Impact factor: 3.752

4.  Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography.

Authors:  Jung-Yoo Chesaria Choi; Cham Albert Choi; In-Sung Luke Yeo
Journal:  J Periodontal Implant Sci       Date:  2018-08-29       Impact factor: 2.614

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.