Literature DB >> 23745950

Attenuated total reflectance-FT-IR spectroscopy for gunshot residue analysis: potential for ammunition determination.

Justin Bueno1, Vitali Sikirzhytski, Igor K Lednev.   

Abstract

The ability to link a suspect to a particular shooting incident is a principal task for many forensic investigators. Here, we attempt to achieve this goal by analysis of gunshot residue (GSR) through the use of attenuated total reflectance (ATR) Fourier transform infrared spectroscopy (FT-IR) combined with statistical analysis. The firearm discharge process is analogous to a complex chemical process. Therefore, the products of this process (GSR) will vary based upon numerous factors, including the specific combination of the firearm and ammunition which was discharged. Differentiation of FT-IR data, collected from GSR particles originating from three different firearm-ammunition combinations (0.38 in., 0.40 in., and 9 mm calibers), was achieved using projection to latent structures discriminant analysis (PLS-DA). The technique was cross (leave-one-out), both internally and externally, validated. External validation was achieved via assignment (caliber identification) of unknown FT-IR spectra from unknown GSR particles. The results demonstrate great potential for ATR-FT-IR spectroscopic analysis of GSR for forensic purposes.

Year:  2013        PMID: 23745950     DOI: 10.1021/ac4011843

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Detection and discrimination of seminal fluid using attenuated total reflectance Fourier transform infrared (ATR FT-IR) spectroscopy combined with chemometrics.

Authors:  Sweety Sharma; Rajinder Singh
Journal:  Int J Legal Med       Date:  2019-12-09       Impact factor: 2.686

2.  Detection of vaginal fluid stains on common substrates via ATR FT-IR spectroscopy.

Authors:  Sweety Sharma; Rajinder Singh
Journal:  Int J Legal Med       Date:  2020-06-15       Impact factor: 2.686

3.  Sex discrimination from urine traces for forensic purposes using attenuated total reflectance Fourier transform infrared spectroscopy and multivariate data analysis.

Authors:  Sweety Sharma; Harpreet Kaur; Rajinder Singh
Journal:  Int J Legal Med       Date:  2022-01-26       Impact factor: 2.791

Review 4.  Scanning electron microscopy and X-ray microanalysis for chemical and morphological characterisation of the inorganic component of gunshot residue: selected problems.

Authors:  Zuzanna Brożek-Mucha
Journal:  Biomed Res Int       Date:  2014-06-15       Impact factor: 3.411

5.  Application of Fourier transform infrared spectroscopy with chemometrics on postmortem interval estimation based on pericardial fluids.

Authors:  Ji Zhang; Bing Li; Qi Wang; Xin Wei; Weibo Feng; Yijiu Chen; Ping Huang; Zhenyuan Wang
Journal:  Sci Rep       Date:  2017-12-21       Impact factor: 4.379

  5 in total