Literature DB >> 23743555

Anesthesia for transcatheter aortic valve implantation: an update.

Steffen Rex1.   

Abstract

PURPOSE OF REVIEW: To summarize and highlight recent advances in the periprocedural management of patients undergoing transcatheter aortic valve implantation (TAVI). RECENT
FINDINGS: TAVI has become the new standard of care in inoperable patients with severe aortic valve stenosis and has emerged as an alternative to surgical aortic valve replacement in patients with high operative risk. Although TAVI is mainly performed via the transfemoral route, other access options are available including the transapical approach. Although TAVI has become a routine procedure, it is still associated with potentially life-threatening complications. TAVI should ideally be performed in a dedicated hybrid room by a multidisciplinary team involving cardiac anesthesiologists. Owing to a lack of validated risk scores, indication and treatment allocation still have to rely on clinical judgment. Owing to the severity of the underlying disease and the complexity of the procedure, TAVI patients require extensive monitoring and installation. The avoidance of prolonged hypotension is the most important goal to prevent hemodynamic deterioration. Transfemoral TAVI procedures can be performed under conscious sedation. Transesophageal echocardiography is an important tool for procedural guidance and the instantaneous detection of complications.
SUMMARY: Anesthesiologists involved in TAVI must have detailed knowledge of valvular heart disease, hemodynamics, echocardiography, the procedure, and associated complications.

Entities:  

Mesh:

Year:  2013        PMID: 23743555     DOI: 10.1097/ACO.0b013e3283628d1e

Source DB:  PubMed          Journal:  Curr Opin Anaesthesiol        ISSN: 0952-7907            Impact factor:   2.706


  3 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Continuous measurement of cardiac output using pulse-contour analysis: truly beat-to-beat?

Authors:  Steffen Rex
Journal:  J Clin Monit Comput       Date:  2014-11-15       Impact factor: 2.502

3.  Transcatheter Aortic Valve Implantation: First Applications and Short Term Outcomes in Our Clinic.

Authors:  Mehmet Aksoy; Ilker Ince; Ali Ahiskalioglu; Nazim Dogan; Abdurrahim Colak; Serdar Sevimli
Journal:  Eurasian J Med       Date:  2015-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.