Literature DB >> 23743100

Abdominal aortic aneurysm imaging with 3-D ultrasound: 3-D-based maximum diameter measurement and volume quantification.

A Long1, L Rouet, A Debreuve, R Ardon, C Barbe, J P Becquemin, E Allaire.   

Abstract

The clinical reliability of 3-D ultrasound imaging (3-DUS) in quantification of abdominal aortic aneurysm (AAA) was evaluated. B-mode and 3-DUS images of AAAs were acquired for 42 patients. AAAs were segmented. A 3-D-based maximum diameter (Max3-D) and partial volume (Vol30) were defined and quantified. Comparisons between 2-D (Max2-D) and 3-D diameters and between orthogonal acquisitions were performed. Intra- and inter-observer reproducibility was evaluated. Intra- and inter-observer coefficients of repeatability (CRs) were less than 5.18 mm for Max3-D. Intra-observer and inter-observer CRs were respectively less than 6.16 and 8.71 mL for Vol30. The mean of normalized errors of Vol30 was around 7%. Correlation between Max2-D and Max3-D was 0.988 (p < 0.0001). Max3-D and Vol30 were not influenced by a probe rotation of 90°. Use of 3-DUS to quantify AAA is a new approach in clinical practice. The present study proposed and evaluated dedicated parameters. Their reproducibility makes the technique clinically reliable.
Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Abdominal; Aortic aneurysm; Imaging; Partial volume; Three-dimensional; Ultrasonography

Mesh:

Year:  2013        PMID: 23743100     DOI: 10.1016/j.ultrasmedbio.2013.03.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

Review 1.  Advanced ultrasound techniques in arterial diseases.

Authors:  Xin Li; Demosthenes Cokkinos; Sameer Gadani; Vasileios Rafailidis; Markus Aschwanden; Abraham Levitin; Diane Szaflarski; Levester Kirksey; Daniel Staub; Sasan Partovi
Journal:  Int J Cardiovasc Imaging       Date:  2022-02-23       Impact factor: 2.357

2.  Feasibility and accuracy of a novel automated three-dimensional ultrasonographic analysis system for abdominal aortic aneurysm: comparison with two-dimensional ultrasonography and computed tomography.

Authors:  In-Jeong Cho; Jinyong Lee; Jinki Park; Sang-Eun Lee; Chul-Min Ahn; Young-Guk Ko; Donghoon Choi; Hyuk-Jae Chang
Journal:  Cardiovasc Ultrasound       Date:  2020-07-01       Impact factor: 2.062

3.  High-Frequency Three-Dimensional Lumen Volume Ultrasound Is a Sensitive Method to Detect Early Aneurysmal Change in Elastase-Induced Murine Abdominal Aortic Aneurysm.

Authors:  Mohammed A Waduud; Parkavi Kandavelu; Melanie Reay; Katherine Paradine; David J A Scott; Marc A Bailey
Journal:  Aorta (Stamford)       Date:  2021-12-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.