Application and experimental validation of an integral method for simulation of gradient-induced eddy currents on conducting surfaces during magnetic resonance imaging.

C T Harris1, D W Haw, W B Handler, B A Chronik.   

Abstract

The time-varying magnetic fields created by the gradient coils in magnetic resonance imaging can produce negative effects on image quality and the system itself. Additionally, they can be a limiting factor to the introduction of non-MR devices such as cardiac pacemakers, orthopedic implants, and surgical robotics. The ability to model the induced currents produced by the switching gradient fields is key to developing methods for reducing these unwanted interactions. In this work, a framework for the calculation of induced currents on conducting surface geometries is summarized. This procedure is then compared to two separate experiments: (1) the analysis of the decay of currents induced upon a conducting cylinder by an insert gradient set within a head only 7 T MR scanner; and (2) analysis of the heat deposited into a small conductor by a uniform switching magnetic field at multiple frequencies and two distinct conductor thicknesses. The method was shown to allow the accurate modeling of the induced time-varying field decay in the first case, and was able to provide accurate estimation of the rise in temperature in the second experiment to within 30% when the skin depth was greater than or equal to the thickness of the conductor.

Mesh:

Year:  2013        PMID: 23739174     DOI: 10.1088/0031-9155/58/12/4367

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.

Authors:  Yujuan Zhao; Tiejun Zhao; Shailesh B Raval; Narayanan Krishnamurthy; Hai Zheng; Chad T Harris; William B Handler; Blaine A Chronik; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2014-11-03       Impact factor: 4.668

2.  An optically coupled sensor for the measurement of currents induced by MRI gradient fields into endocardial leads.

Authors:  Eugenio Mattei; Federica Censi; Michele Triventi; Antonio Napolitano; Elisabetta Genovese; Vittorio Cannatà; Giovanni Calcagnini
Journal:  MAGMA       Date:  2014-10-11       Impact factor: 2.310

3.  Heating of hip joint implants in MRI: The combined effect of RF and switched-gradient fields.

Authors:  Alessandro Arduino; Umberto Zanovello; Jeff Hand; Luca Zilberti; Rüdiger Brühl; Mario Chiampi; Oriano Bottauscio
Journal:  Magn Reson Med       Date:  2021-01-22       Impact factor: 4.668

4.  A contribution to MRI safety testing related to gradient-induced heating of medical devices.

Authors:  Alessandro Arduino; Oriano Bottauscio; Mario Chiampi; Umberto Zanovello; Luca Zilberti
Journal:  Magn Reson Med       Date:  2022-03-28       Impact factor: 3.737

5.  Feasibility of Imaging Tissue Electrical Conductivity by Switching Field Gradients with MRI.

Authors:  Eric Gibbs; Chunlei Liu
Journal:  Tomography       Date:  2015-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.