Plantar pressure of clipless and toe-clipped pedals in cyclists - A pilot study.

Andrea Davis1, Troy Pemberton, Subhajit Ghosh, Nicola Maffulli, Nat Padhiar.   

Abstract

To determine the effect of clipless and toe-clipped pedals on plantar foot pressure while cycling. Seven bikers and 11 healthy volunteers were tested on a Giant ATX Team mountain bike, Tekscan Clinical 5.24 F-scan® system with an inner sole pressure sensor, a Tacx Cycle force One Turbo Trainer and a Cateye Mity 8 computerized speedometer were used. The subjects wore Shimano M037 shoes and used a standard clipless and toe-clipped pedal. The seat height was set at 100% of subject's trochanteric height. Plantar pressures were recorded over 12 consecutive crank cycles at a constant speed for each of the power outputs. The videos were analysed to record the pressure exerted at 12 positions on the foot for each variable. Whether there is any dominance of any of the metatarsals, and any difference in plantar pressures between clipped and clipless pedal. There was a significant difference in the pressure at many positions of the foot, but the sites were different for each individual. General regression analysis indicated that pedal type had a statistically significant effect on plantar pressure at the sites of 1(st) metatarsal (p=0.042), 3(rd) metatarsal (p<0.001), 5(th) metatarsal (<0.001), 2(nd) (p=0.018) and 5(th) toe (p<0.001), lateral midfoot (p<0.001) and central heel (p<0.001) areas. Clipless pedals produce higher pressures which are more spread across the foot than toe-clipped pedals. This may have implications for their use in the prevention and/or management of overuse injuries in the knee and foot.

Entities:  

Keywords:  Hellp cycling; chronic exercise induced comportment syndrome; compartment pressures; training

Year:  2011        PMID: 23738240      PMCID: PMC3666464     

Source DB:  PubMed          Journal:  Muscles Ligaments Tendons J        ISSN: 2240-4554


  19 in total

1.  Biomechanical loading in the triple jump.

Authors:  J O Perttunen; H Kyröläinen; P V Komi; A Heinonen
Journal:  J Sports Sci       Date:  2000-05       Impact factor: 3.337

2.  The effect of lower-limb anatomy on knee loads during seated cycling.

Authors:  P Ruby; M L Hull; K A Kirby; D W Jenkins
Journal:  J Biomech       Date:  1992-10       Impact factor: 2.712

Review 3.  [Distal nerve compression of the leg. Clinical and electrophysiologic study].

Authors:  D Mabin
Journal:  Neurophysiol Clin       Date:  1997       Impact factor: 3.734

4.  Asymmetry in bicycle ergometer pedalling.

Authors:  D J Daly; P R Cavanagh
Journal:  Med Sci Sports       Date:  1976

5.  Measurement of dynamic pressures at the shoe-foot interface during normal walking with various foot orthoses using the FSCAN system.

Authors:  M Brown; S Rudicel; A Esquenazi
Journal:  Foot Ankle Int       Date:  1996-03       Impact factor: 2.827

6.  The effect of bicycle seat height variation upon oxygen consumption and lower limb kinematics.

Authors:  K S Nordeen-Snyder
Journal:  Med Sci Sports       Date:  1977

7.  Abstracts of NACOB II. The 2nd North American Congress on Biomechanics.

Authors: 
Journal:  J Biomech       Date:  1993-03       Impact factor: 2.712

8.  Lower extremity overuse in bicycling.

Authors:  J C Holmes; A L Pruitt; N J Whalen
Journal:  Clin Sports Med       Date:  1994-01       Impact factor: 2.182

Review 9.  Biomechanical factors associated with shoe/pedal interfaces. Implications for injury.

Authors:  R J Gregor; J B Wheeler
Journal:  Sports Med       Date:  1994-02       Impact factor: 11.136

10.  The effects of cycling shoe stiffness on forefoot pressure.

Authors:  Nathan Edward Jarboe; Peter M Quesada
Journal:  Foot Ankle Int       Date:  2003-10       Impact factor: 2.827

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.