| Literature DB >> 23736246 |
Nicholas Hopps1, Colin Danson, Stuart Duffield, David Egan, Stephen Elsmere, Mark Girling, Ewan Harvey, David Hillier, Michael Norman, Stefan Parker, Paul Treadwell, David Winter, Thomas Bett.
Abstract
The commissioning of the Orion laser facility at the Atomic Weapons Establishment (AWE) in the UK has recently been completed. The facility is a twelve beam Nd:glass-based system for studying high energy density physics. It consists of ten frequency-tripled beam-lines operating with nanosecond pulses, synchronized with two beam-lines with subpicosecond pulses, each capable of delivering 500 J to target. One of the short pulse beams has the option of frequency doubling, at reduced aperture, to yield up to 100 J at 527 nm in a subpicosecond pulse with high temporal contrast. An extensive array of target diagnostics is provided. This article describes the laser design and commissioning and presents key performance data of the facility's laser systems.Year: 2013 PMID: 23736246 DOI: 10.1364/AO.52.003597
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980