Electrophysiological evaluation of atrioventricular conduction disturbances in transcatheter aortic valve implantation with Edwards SAPIEN prosthesis.

Abdurrahman Eksik1, Mehmet Gul, Huseyin Uyarel, Ozgur Surgit, Aydin Yildirim, Nevzat Uslu, Huseyin Aksu, Selahattin Turen, Fazih Uzun, Hulusi Satılmısoglu, Mustafa Kemal Erol, Ihsan Bakir.   

Abstract

AIMS: Permanent pacemaker requirement is a known complication after transcatheter aortic valve implantation (TAVI). The aim of the present study was to analyze the effects of Edwards SAPIEN prosthesis implantation on atrioventricular conduction.
METHODS: The study included 28 patients who underwent TAVI due to severe aortic valve stenosis. An electrophysiological study was performed in the catheterization room immediately before the initial balloon valvuloplasty and immediately after Edwards SAPIEN prosthesis implantation.
RESULTS: His-ventricle interval was significantly prolonged postprocedure (55.9 ± 11.5 ms) vs preprocedure (47.3 ± 7.8 ms) (P<.001). The antegrade Wenckebach point was observed to be significantly prolonged postprocedure (354.4 ± 41.3 ms) vs preprocedure (333.7 ± 45.4 ms) (P=.001). Despite atrial-His interval prolongation, it was not statistically significant. After the procedure, we observed significant conduction disturbances in 3 patients (10.7%). These conduction problems recovered before discharge. One of the patients (3.6%) with right bundle branch block + left anterior fascicular block required permanent pacemaker implantation. At postprocedure electrocardiogram, QRS duration increased, QRS axis shifted to the left, and both of the values became normal before discharge. The patient's echocardiographic and clinical parameters were improved during follow-up.
CONCLUSION: The effect of Edwards SAPIEN on the conduction system was mostly infranodal and temporary. The physical properties of the Edwards SAPIEN prosthesis may explain this observation. This complication may be lessened if the frame height characteristics can be improved.

Entities:  

Mesh:

Year:  2013        PMID: 23735359

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  8 in total

1.  Management of Coronary Artery Disease and Conduction Abnormalities in Transcatheter Aortic Valve Implantation.

Authors:  Anna Kostopoulou; Panagiotis Karyofillis; Efthimios Livanis; George Karavolias; George Theodorakis; John Paraskevaides; Vassilis Voudris
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-02

2.  Complete atrioventricular block improved by balloon aortic valvuloplasty for severe aortic stenosis: Usefulness of sheathless technique in the retrograde approach.

Authors:  Hidenori Matsusaka; Yusuke Akiyama; Toshihiko Kubo
Journal:  J Cardiol Cases       Date:  2016-03-10

3.  Evaluation of the 2021 European Society of Cardiology guidelines in pre-existing right bundle branch block patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve.

Authors:  Toshiaki Isogai; Iryna Dykun; Ankit Agrawal; Shashank Shekhar; Khaldoun G Tarakji; Oussama M Wazni; Ankur Kalra; Amar Krishnaswamy; Grant W Reed; Samir R Kapadia; Rishi Puri
Journal:  Eur Heart J Open       Date:  2022-03-11

4.  Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique.

Authors:  Fortunato Iacovelli; Giuseppe Giugliano; Donato Gerardi; Luigi Salemme; Angelo Cioppa; Armando Pucciarelli; Grigore Popusoi; Francesco Loizzi; Giancarlo Schettino; Stefano Favale; Francesco Solimene; Giovanni Esposito; Tullio Tesorio; Eugenio Stabile
Journal:  Heart Vessels       Date:  2021-09-15       Impact factor: 2.037

5.  Prognosis assessment of persistent left bundle branch block after TAVI by an electrophysiological and remote monitoring risk-adapted algorithm: rationale and design of the multicentre LBBB-TAVI Study.

Authors:  Grégoire Massoullié; Pierre Bordachar; Didier Irles; Christophe Caussin; Antoine Da Costa; Pascal Defaye; Frédéric Jean; Alexis Mechulan; Pierre Mondoly; Géraud Souteyrand; Bruno Pereira; Sylvain Ploux; Romain Eschalier
Journal:  BMJ Open       Date:  2016-10-26       Impact factor: 2.692

Review 6.  Conduction abnormalities after transcatheter aortic valve implantation.

Authors:  Panagiotis Karyofillis; Anna Kostopoulou; Sofia Thomopoulou; Martha Habibi; Efthimios Livanis; George Karavolias; Vassilis Voudris
Journal:  J Geriatr Cardiol       Date:  2018-01       Impact factor: 3.327

Review 7.  Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management.

Authors:  Krzysztof Wilczek; Rafał Reguła; Kamil Bujak; Piotr Chodór; Michał Długaszek; Mariusz Gąsior
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-08-19       Impact factor: 1.426

8.  Electrophysiology Testing to Stratify Patients With Left Bundle Branch Block After Transcatheter Aortic Valve Implantation.

Authors:  Sven Knecht; Beat Schaer; Tobias Reichlin; Florian Spies; Antonio Madaffari; Annina Vischer; Gregor Fahrni; Raban Jeger; Christoph Kaiser; Stefan Osswald; Christian Sticherling; Michael Kühne
Journal:  J Am Heart Assoc       Date:  2020-02-22       Impact factor: 5.501

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.