Literature DB >> 23731682

Benefits of active oxygenation during hypothermic machine perfusion of kidneys in a preclinical model of deceased after cardiac death donors.

Raphaël Thuillier1, Geraldine Allain, Olivier Celhay, William Hebrard, Benoit Barrou, Lionel Badet, Henri Leuvenink, Thierry Hauet.   

Abstract

BACKGROUND: Deceased after cardiac death donors (DCDs) represent a valuable source of organs; however, preventing poor outcome is difficult, even with the use of machine perfusion (MP). It is of paramount importance to improve this method. We proposed to evaluate the benefits of active oxygenation during kidney graft hypothermic MP using a novel perfusion machine: Kidney Assist (KA).
METHODS: We used a pig model of DCD transplantation in Large White pigs. Cold preservation was performed by conventional non-oxygenated MP (KAnoO2) or oxygenated MP (KA).
RESULTS: In the first 2 wk post-transplant, KA grafts displayed a lower serum creatinine peak and a faster return to normal levels compared with KAnoO2 animals, translating into a smaller area under the curve. Urinary neutrophil gelatinase-associated lipocalin levels and serum aspartate amino transferase levels were lower in KA animals compared with the non-oxygenated group. These correlated with better chronic function. Longer follow-up of the animals (3 mo) permitted evaluation of chronic outcome lesions. Interstitial fibrosis was reduced in the KA group, and these kidneys also displayed significantly lower levels of vimentin staining. Further histologic investigation also showed a trend toward decreased chronic inflammation in kidneys preserved with oxygen.
CONCLUSIONS: This new MP system is efficient in preserving DCD kidneys, greatly enhancing the capacity of the graft to withstand preservation stress and improving outcome. Oxygen delivery during preservation is thus valuable for highly damaged organs and offers an important therapeutic tool for transplant teams faced with decreased quality of donor organs.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  DCD; Kidney transplantation; Machine perfusion; Marginal donors; Oxygen; Preclinical

Mesh:

Substances:

Year:  2013        PMID: 23731682     DOI: 10.1016/j.jss.2013.04.071

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  24 in total

Review 1.  What is the evidence for oxygenation during kidney preservation for transplantation in 2021? A scoping review.

Authors:  B Mesnard; A E Ogbemudia; G Karam; F Dengu; G Hackim; J Rigaud; G Blancho; S Drouin; M O Timsit; J Branchereau
Journal:  World J Urol       Date:  2021-08-25       Impact factor: 3.661

2.  Magnetic resonance imaging assessment of renal flow distribution patterns during ex vivo normothermic machine perfusion in porcine and human kidneys.

Authors:  Rianne Schutter; Veerle A Lantinga; Tim L Hamelink; Merel B F Pool; Otis C van Varsseveld; Jan Hendrik Potze; Jan-Luuk Hillebrands; Marius C van den Heuvel; Rudi A J O Dierckx; Henri G D Leuvenink; Cyril Moers; Ronald J H Borra
Journal:  Transpl Int       Date:  2021-09       Impact factor: 3.842

3.  Brief Bubble and Intermittent Surface Oxygenation Is a Simple and Effective Alternative for Membrane Oxygenation During Hypothermic Machine Perfusion in Kidneys.

Authors:  Tom Darius; Martial Vergauwen; Matteo Mueller; Selda Aydin; Philipp Dutkowski; Pierre Gianello; Michel Mourad
Journal:  Transplant Direct       Date:  2020-06-11

4.  Continuous Normothermic Ex Vivo Kidney Perfusion Improves Graft Function in Donation After Circulatory Death Pig Kidney Transplantation.

Authors:  J Moritz Kaths; Juan Echeverri; Yi Min Chun; Jun Yu Cen; Nicolas Goldaracena; Ivan Linares; Luke S Dingwell; Paul M Yip; Rohan John; Darius Bagli; Istvan Mucsi; Anand Ghanekar; David R Grant; Lisa A Robinson; Markus Selzner
Journal:  Transplantation       Date:  2017-04       Impact factor: 4.939

5.  Heterotopic Renal Autotransplantation in a Porcine Model: A Step-by-Step Protocol.

Authors:  J Moritz Kaths; Juan Echeverri; Nicolas Goldaracena; Kristine S Louis; Paul Yip; Rohan John; Istvan Mucsi; Anand Ghanekar; Darius Bagli; Markus Selzner; Lisa A Robinson
Journal:  J Vis Exp       Date:  2016-02-21       Impact factor: 1.355

Review 6.  Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis.

Authors:  Ahmer M Hameed; Henry C Pleass; Germaine Wong; Wayne J Hawthorne
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

Review 7.  Role of temperature in reconditioning and evaluation of cold preserved kidney and liver grafts.

Authors:  Thomas Minor; Charlotte von Horn; Andreas Paul
Journal:  Curr Opin Organ Transplant       Date:  2017-06       Impact factor: 2.640

8.  Successful Dual Kidney Transplantation After Hypothermic Oxygenated Perfusion of Discarded Human Kidneys.

Authors:  Matteo Ravaioli; Vanessa De Pace; Giorgia Comai; Marco Busutti; Massimo Del Gaudio; Annalisa Amaduzzi; Alessandro Cucchetti; Antonio Siniscalchi; Gaetano La Manna; Antonietta A D D'Errico; Antonio Daniele Pinna
Journal:  Am J Case Rep       Date:  2017-09-20

9.  Opportunities for Therapeutic Intervention During Machine Perfusion.

Authors:  Negin Karimian; Heidi Yeh
Journal:  Curr Transplant Rep       Date:  2017-04-19

10.  Reduction of Renal Preservation/Reperfusion Injury by Controlled Hyperthermia During Ex Vivo Machine Perfusion.

Authors:  Thomas Minor; Charlotte von Horn
Journal:  Clin Transl Sci       Date:  2020-10-27       Impact factor: 4.689

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.