Literature DB >> 23731310

One-year results of the multilayer flow modulator stent in the management of thoracoabdominal aortic aneurysms and type B dissections.

Sherif Sultan1, Niamh Hynes.   

Abstract

PURPOSE: To report 1-year results from the first subgroup of patients treated with the Multilayer Flow Modulator (MFM) stent for aortic aneurysm and dissection.
METHODS: Up to December 2012, 243 patients have been treated worldwide for aortic aneurysm and dissection with the Cardiatis MFM under the established indications for use. This retrospective review encompasses the first 55 of these patients (41 men; mean age 64.5±18 years), who were treated on a compassionate basis in 11 countries. There were 31 thoracoabdominal aortic aneurysms (8 Crawford type I, 3 type II, 9 type III, and 11 type IV), 7 arch aneurysms, 3 infrarenal abdominal aortic aneurysms, 8 suprarenal aortic aneurysms, and 6 type B dissections. Mean aneurysm diameter was 6.04±1.66 cm, and the mean length was 11.58±7.62 cm. The primary endpoint at 1 year was a composite of rupture and aneurysm-related death. The secondary endpoints were all-cause mortality, visceral branch occlusion, adverse events (i.e., stroke and paraplegia), and reintervention.
RESULTS: Technical success was 98.2%; there was no paraplegia or perioperative visceral or renal insult. The mean number of side branches covered was 3.7±1.3 per case (range 0-6); 108 stents were deployed (range 1-5). At 1 year, aneurysm-related survival was 93.7%, all-cause survival was 84.8%, intervention-free survival was 92.4%, and all of the 202 side branches were patent. There were no stent fractures. At 6 months, the mean rate of sac volume increase was 0.36% per month, resulting in a mean volume increase of 2.14%. At 12 months, the rate of increase had slowed to 0.28% per month, resulting in a total average increase in sac volume of 3.26%. The ratio of thrombus to total volume stayed almost constant over the 12 months at 0.48, while the ratio of flow to total volume fell from 0.21 to 0.12 at 12 months.
CONCLUSION: MFM implantation instigates a process of aortic remodeling involving initial thrombus deposition, which slowed between 6 and 12 months. Increasing sac size did not herald rupture, and the MFM was not associated with loss of native side branches. With physiological modulation of the aneurysm, the MFM offers promise for resolution of complex thoracoabdominal pathology with off-the-shelf availability, but this disruptive technology requires further development and technical refinement. Long-term follow-up of the registry patients is mandatory before establishing a randomized controlled study.

Entities:  

Mesh:

Year:  2013        PMID: 23731310     DOI: 10.1583/12-4077MR-R.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  11 in total

Review 1.  [Thoracoabominal aortic aneurysms-endovascular options].

Authors:  M Gschwendtner
Journal:  Radiologe       Date:  2018-09       Impact factor: 0.635

2.  Aortic Dissection: Novel Surgical Hybrid Procedures.

Authors:  Alessandro Cannavale; Mariangela Santoni; Fabrizio Fanelli; Gerard O'Sullivan
Journal:  Interv Cardiol       Date:  2017-05

3.  Late surgical conversion of failed Multilayer Flow Modulator stenting in thoraco-abdominal aneurysms.

Authors:  Simone Salvati; Victor Bilman; Andrea Melloni; Domenico Baccellieri; Andrea Kahlberg; Germano Melissano; Roberto Chiesa; Luca Bertoglio
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-08-07

4.  Multilayer stents affect the final diameter of aortic aneurysms and maintain renal artery patency for a short time in a swine experimental model.

Authors:  Anna Paula Weinhardt Baptista-Strazzi; Ricardo Aun; Igor Rafael Sincos; Allana M Tobita; Maria Fernanda Cassino Portugal; Vitória Penido de Paula; Oskar Kaufmann; Nelson Wolosker
Journal:  Clinics (Sao Paulo)       Date:  2021-05-21       Impact factor: 2.365

5.  Management of complicated aortic aneurysms using multiple overlapping uncovered stents: mid-term outcome from a cohort study.

Authors:  Yongxue Zhang; Zhongzhao Teng; Qingsheng Lu; Zhiqing Zhao; Junmin Bao; Xiang Feng; Rui Feng; Zengsheng Chen; Yuan Huang; Umar Sadat; Jonathan H Gillard; Zaiping Jing
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

6.  Finite element modeling of a novel self-expanding endovascular stent method in treatment of aortic aneurysms.

Authors:  Mark C Arokiaraj; Igor F Palacios
Journal:  Sci Rep       Date:  2014-01-10       Impact factor: 4.379

7.  Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm.

Authors:  Siang Lin Yeow; Hwa Liang Leo
Journal:  Comput Math Methods Med       Date:  2016-05-09       Impact factor: 2.238

8.  Is endovascular treatment with multilayer flow modulator stent insertion a safe alternative to open surgery for high-risk patients with thoracoabdominal aortic aneurysm?

Authors:  Carolline Pinto; George Garas; Leanne Harling; Ara Darzi; Roberto Casula; Thanos Athanasiou
Journal:  Ann Med Surg (Lond)       Date:  2017-01-31

9.  Endovascular management of renal artery aneurysms using the multilayer flow modulator.

Authors:  Sherif Sultan; Mahmoud Basuoniy Alawy; Rita Flaherty; Edel P Kavanagh; Mohamed Elsherif; Ala Elhelali; Florian Stefanov; Violet Lundon; Niamh Hynes
Journal:  Open Heart       Date:  2016-03-10

Review 10.  Contemporary strategies for repair of complex thoracoabdominal aortic aneurysms: real-world experiences and multilayer stents as an alternative.

Authors:  Ralf Robert Kolvenbach
Journal:  J Vasc Bras       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.