Literature DB >> 23731294

Endovascular aortic repair of thoracic aortic disease: early and 1-year results from a German multicenter registry.

Ralf Zahn1, Raimund Erbel, Christoph A Nienaber, Franz-Josef Neumann, Holger Nef, Holger Eggebrecht, Jochen Senges.   

Abstract

PURPOSE: To report a "real-world" multicenter experience in the use of thoracic endovascular aortic repair (TEVAR) for diseases of the descending thoracic aorta.
METHODS: A prospective, multicenter, German TEVAR Registry was established in October 2008 and enrolled 191 patients (134 men; mean age 64.5±13.2 years) from 7 hospitals up to March 2011. Stent-graft implantation was performed for Stanford type B aortic dissection (104, 55.3%), true thoracic aortic aneurysm (91, 48.7%), intramural hematoma (20, 10.7%), penetrating aortic ulcer (16, 8.6%), and traumatic aortic rupture (6, 3.2%).
RESULTS: Per patient, a mean of 1.2±0.7 stent-grafts were implanted. Technical success was 92.1% (164/178); 15 (8.5%) endoleaks (types I-III) were reported. Intervention duration was a mean 107±122 minutes. During the hospital stay, stroke occurred in 3.9% of patients (7/180) and paraplegia in 1.7% (3/180). Reintervention was performed in 3.3% (6/180). The mortality was 5.5% (10/181) in-hospital and 5.6% at 30 days. The mean follow-up was 24.5±27.7 months. The Kaplan-Meier estimates of 1-year reintervention and death rates were 7.2% and 11.4%, respectively.
CONCLUSION: In this real-world TEVAR registry for acute or chronic descending aortic diseases, technical success was high and the short-term complication rate was acceptable. However, the high reintervention rate observed in the present study mandates thorough clinical and imaging follow-up after an initially successful procedure.

Entities:  

Mesh:

Year:  2013        PMID: 23731294     DOI: 10.1583/12-4107R.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  5 in total

1.  Implantation study of a tissue-engineered self-expanding aortic stent graft (bio stent graft) in a beagle model.

Authors:  Hidetake Kawajiri; Takeshi Mizuno; Takeshi Moriwaki; Ryosuke Iwai; Hatsue Ishibashi-Ueda; Masashi Yamanami; Keiichi Kanda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2014-10-16       Impact factor: 1.731

Review 2.  The role of multidetector-row CT in the diagnosis, classification and management of acute aortic syndrome.

Authors:  A Abbas; I W Brown; C R Peebles; S P Harden; J S Shambrook
Journal:  Br J Radiol       Date:  2014-08-01       Impact factor: 3.039

3.  Case report of an endovascular repair of a residual type A dissection using a not CE not FDA-approved Najuta thoracic stent graft system.

Authors:  N Mangialardi; S Ronchey; A Malaj; M Lachat; E Serrao; V Alberti; S Fazzini
Journal:  Medicine (Baltimore)       Date:  2015-01       Impact factor: 1.889

Review 4.  Diagnosing Aortic Intramural Hematoma: Current Perspectives.

Authors:  Carlos Ferrera; Isidre Vilacosta; Beatriz Cabeza; Javier Cobiella; Isaac Martínez; Melchor Saiz-Pardo Sanz; Ana Bustos; Francisco Javier Serrano; Luis Maroto
Journal:  Vasc Health Risk Manag       Date:  2020-06-08

5.  A New Era of Diagnosis and Therapy in Acute Aortic Syndromes: The Mainz-Essen Experience (Part II)-Management and Outcomes.

Authors:  Eduardo Bossone; Riccardo Gorla; Brigida Ranieri; Valentina Russo; Heinz Jakob; Raimund Erbel
Journal:  Aorta (Stamford)       Date:  2021-12-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.