Literature DB >> 23730778

Microchip emitter for solid-phase extraction-gradient elution-mass spectrometry.

Natalia Gasilova1, Liang Qiao, Dmitry Momotenko, Mohammad Reza Pourhaghighi, Hubert H Girault.   

Abstract

A microchip electrospray emitter with a magnetic bead trap has been designed for solid-phase extraction-gradient elution-mass spectrometry (SPE-GEMS). The goal of this method is the detection of analytes at low concentrations and it is here demonstrated using reverse phase coated magnetic beads (Mbs) for the preconcentration and detection of the peptides. The sample is passed through the chip, and the peptides are retained and enriched in the trap. After washing, the peptides are released sequentially by stepwise gradient elution and electrosprayed for mass spectrometry analysis. This approach allows effective sample desalting, enrichment, sequential elution, and MS detection without the introduction of an additional separation step after SPE. Efficient preconcentration of model peptides by SPE and sequential release and analysis of peptides by GEMS were demonstrated for diluted sample solutions within the range of 1 μM to 10 nM. Fortified human blood serum, protein digest and fractions collected after protein digest OFFGEL separation were analyzed by SPE-GEMS allowing the detection of low abundance peptides usually not observed by direct mass spectrometry analysis. A mathematical model for gradient elution is proposed.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23730778     DOI: 10.1021/ac400171e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Monitoring cell secretions on microfluidic chips using solid-phase extraction with mass spectrometry.

Authors:  Colleen E Dugan; James P Grinias; Sebastian D Parlee; Mahmoud El-Azzouny; Charles R Evans; Robert T Kennedy
Journal:  Anal Bioanal Chem       Date:  2016-10-19       Impact factor: 4.142

2.  On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes.

Authors:  Xiaoqin Zhong; Liang Qiao; Géraldine Stauffer; Baohong Liu; Hubert H Girault
Journal:  J Am Soc Mass Spectrom       Date:  2018-03-20       Impact factor: 3.109

3.  Biomonitoring of perfluorinated compounds in a drop of blood.

Authors:  Pan Mao; Daojing Wang
Journal:  Environ Sci Technol       Date:  2015-05-22       Impact factor: 9.028

4.  Microfluidic Flow-through SPME Chip for Online Separation and MS Detection of Multiple Analyses in Complex Matrix.

Authors:  Yujun Chen; Tao Gong; Cilong Yu; Xiang Qian; Xiaohao Wang
Journal:  Micromachines (Basel)       Date:  2020-01-21       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.