Literature DB >> 23730420

Surgical treatment of the atrophic mandibular fractures by locked plates systems: our experience and a literature review.

Giorgio Novelli1, Cristiano Sconza, Emanuela Ardito, Alberto Bozzetti.   

Abstract

The management of atrophic mandibular fractures in edentulous patients represents an insidious issue for the maxillofacial surgeon due to the biological and biomechanical conditions that are unfavorable for fracture fixation and bone healing. The purpose of this study was to evaluate the results of the treatment of atrophic mandibular fractures and to compare the outcomes of different plating systems used for stabilization. We selected a study group of 16 patients with fractures of completely edentulous atrophic mandibles who were treated in our department between 2004 and 2010. All patients were surgically treated by open reduction and internal rigid fixation using 2.0-mm large-profile locking and 2.4-mm locking bone plates. All patients achieved a complete fracture healing and fast functional recovery of mandibular movements without intraoperative or postoperative surgical complications. The results of our study demonstrated the efficacy of this type of treatment in association with a low postoperative complication rate, a reduction in the recovery time, and the possibility to have an immediately functional rehabilitation. There were very similar results using each of the two bone plating methods considered: no case had hardware failure or nonunion of the fracture. The 2.0-mm large locking plate is thinner, exposes through the soft tissues less frequently, and is much easier to shape and adapt to the mandibular anatomy. However, the 2.4-mm locking plate system still represents the reference hardware in the condition of severe bone atrophy.

Entities:  

Keywords:  edentulous; fracture fixation; mandibular atrophy; mandibular fractures; plate systems

Year:  2012        PMID: 23730420      PMCID: PMC3444021          DOI: 10.1055/s-0031-1300961

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  17 in total

1.  Invasive management of the fractured atrophic edentulous mandible.

Authors:  R D Marciani
Journal:  J Oral Maxillofac Surg       Date:  2001-07       Impact factor: 1.895

2.  Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates.

Authors:  Richard H Haug; Chad C Street; Michele Goltz
Journal:  J Oral Maxillofac Surg       Date:  2002-11       Impact factor: 1.895

3.  Miniplate osteosynthesis for fractures of the edentulous mandible: a clinical study 1989-96.

Authors:  I Iatrou; C Samaras; N Theologie-Lygidakis
Journal:  J Craniomaxillofac Surg       Date:  1998-12       Impact factor: 2.078

4.  An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model.

Authors:  J W Sikes; B R Smith; D P Mukherjee
Journal:  J Oral Maxillofac Surg       Date:  2000-01       Impact factor: 1.895

Review 5.  Management of the fractured edentulous atrophic mandible.

Authors:  M Nasser; Z Fedorowicz; A Ebadifar
Journal:  Cochrane Database Syst Rev       Date:  2007-01-24

6.  Management of the edentulous/atrophic mandibular fracture.

Authors:  Shahid R Aziz; Talib Najjar
Journal:  Atlas Oral Maxillofac Surg Clin North Am       Date:  2009-03

7.  Treatment protocol for fractures of the atrophic mandible.

Authors:  Edward Ellis; Chris Price
Journal:  J Oral Maxillofac Surg       Date:  2008-03       Impact factor: 1.895

8.  A biomechanical comparison of 2 techniques for reconstructing atrophic edentulous mandible fractures.

Authors:  Matthew J Madsen; Richard H Haug
Journal:  J Oral Maxillofac Surg       Date:  2006-03       Impact factor: 1.895

9.  Macroplate fixation of fractures of the edentulous atrophic mandible: immediate function and masticatory rehabilitation.

Authors:  Steffen Müller; Ralf Bürgers; Michael Ehrenfeld; Martin Gosau
Journal:  Clin Oral Investig       Date:  2010-01-12       Impact factor: 3.573

10.  Results of treatment of fractures of the atrophic edentulous mandible by compression plating: a retrospective evaluation of 84 consecutive cases.

Authors:  H G Luhr; T Reidick; H A Merten
Journal:  J Oral Maxillofac Surg       Date:  1996-03       Impact factor: 1.895

View more
  5 in total

1.  Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases.

Authors:  Leandro Benetti de Oliveira; Marisa Aparecida Cabrini Gabrielli; Mario Francisco Real Gabrielli; Valfrido Antonio Pereira Pereira-Filho
Journal:  Oral Maxillofac Surg       Date:  2015-05-22

Review 2.  [Current therapy of atrophic edentulous mandibular fractures among elderly people].

Authors:  Li Mingzhe; Xu Xiaofeng; Xu Bing
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-08-01

3.  Circummandibular Wires for Treatment of Dentoalveolar Fractures Adjacent to Edentulous Areas: A Report of Two Cases.

Authors:  Karl Maloney
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-01-13

4.  Treatment of edentulous mandibular fractures with rigid internal fixation: case series and literature review.

Authors:  Edgardo Franciosi; Eduardo Mazzaro; Juan Larranaga; Alfredo Rios; Pedro Picco; Marcelo Figari
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-01-14

5.  Extraction of impacted third molar with preventive installation of titanium miniplate: Case report.

Authors:  Joanna Gaba Feniar; Humberto Kawano; Gisela Cristina Vianna Camolesi; Michelle Palmieri; Sérgio De Souza Sobral; Fábio Lopes Duarte; Marcos José Barboni Maringoli; Henrique Camargo Bauer; Waldyr Antônio Jorge; Renata Matalon Negreiros
Journal:  Ann Med Surg (Lond)       Date:  2019-11-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.