Literature DB >> 23728935

Collagen fiber alignment and maximum principal strain in the glenohumeral capsule predict location of failure during uniaxial extension.

Carrie A Voycheck1, Kelvin Luu, Patrick J McMahon, Richard E Debski.   

Abstract

The glenohumeral joint is frequently dislocated resulting in injury to the glenohumeral capsule. Repair techniques that focus on restoring the capsule after dislocation to re-establish its stabilizing function could benefit from predictions of the location of failure in this continuous sheet of tissue with a random collagen fiber alignment in the unloaded state. Therefore, the objective of this study was to determine the collagen fiber alignment and maximum principal strain in all regions of the capsule during uniaxial extension to failure and to determine whether these parameters could predict the location of tissue failure. Collagen fiber alignment, quantified using a small-angle light-scattering device, and maximum principal strain in the capsule were determined at 5% increments of elongation until tissue failure. A contingency table analyzed with Fischer's exact test demonstrated that peak collagen fiber alignment, represented by the normalized orientation index (p < 0.001) and maximum principal strain (p < 0.001), is significant in predicting location of failure. The direct correlation between the maximum principal strain and collagen fiber alignment measured prior to failure to the location of tissue failure suggests these parameters can be used as a predictive tool to help locate the areas of the glenohumeral capsule that are susceptible to failure. In the future, changes in collagen fiber alignment following injury could be used to develop a constitutive model for injured capsular tissue.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23728935     DOI: 10.1007/s10237-013-0503-2

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  3 in total

1.  A Large-Scale Computational Analysis of Corneal Structural Response and Ectasia Risk in Myopic Laser Refractive Surgery.

Authors:  William Joseph Dupps; Ibrahim Seven
Journal:  Trans Am Ophthalmol Soc       Date:  2016-08

2.  Multiscale mechanics of the cervical facet capsular ligament, with particular emphasis on anomalous fiber realignment prior to tissue failure.

Authors:  Sijia Zhang; Vahhab Zarei; Beth A Winkelstein; Victor H Barocas
Journal:  Biomech Model Mechanobiol       Date:  2017-08-18

3.  Planar biaxial extension of the lumbar facet capsular ligament reveals significant in-plane shear forces.

Authors:  Amy A Claeson; Victor H Barocas
Journal:  J Mech Behav Biomed Mater       Date:  2016-08-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.