Literature DB >> 23727873

Optimized extraction method for LC-MS determination of bisphenol A, melamine and di(2-ethylhexyl) phthalate in selected soft drinks, syringes, and milk powder.

Alaa Khedr1.   

Abstract

Described below is an optimized solid-phase extraction method (SPE) for the simultaneous determination of three hazardous plastic additives. Two high-performance liquid chromatographic-electrospray ionization-mass spectrometric (HPLC-ESI-MS) methods were developed and validated to estimate the melamine (MEL), bis(2-ethylhexyl) phthalate (DEHP), and bisphenol A (BPA) contents in drinking water, syringes, soft drinks, and dry milk powder. One extraction procedure optimally recovered all three substances from the different matrices. Two extraction columns were combined and included a silica gel LiChroprep RP-2 column (20:1, g/g, top column) and a Sep-Pak with a C18 column (500mg, bottom column). The analytical column was an Agilent Eclipse XDB-C8 column, 4.6mm×150mm, 5μm, maintained at 50±2°C. MEL and DEHP were monitored by positive triple quad mass spectrometry (TQ-MS) using an acidic mobile phase, while BPA was monitored by negative TQ-MS using a mobile phase containing a 0.05% ammonia solution. The general linear range of the three compounds ranged from 12 to 1000pg/μL in the injected solution (25μL). The average extraction recoveries were within the range of 83.0-102.5%. Relatively high concentrations of BPA and DEHP were found in the milk powder and sterile syringes.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23727873     DOI: 10.1016/j.jchromb.2013.04.040

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  A simple magnetic solid-phase extraction method based on magnetite/graphene oxide nanocomposite for pre-concentration and determination of melamine by high-performance liquid chromatography.

Authors:  Hossein Abdolmohammad-Zadeh; Abbasali Zamani; Zahra Shamsi
Journal:  Environ Sci Pollut Res Int       Date:  2020-01-11       Impact factor: 4.223

2.  The association of socio-demographic status, lifestyle factors and dietary patterns with total urinary phthalates in Australian men.

Authors:  Peter Y Bai; Gary A Wittert; Anne W Taylor; Sean A Martin; Robert W Milne; Zumin Shi
Journal:  PLoS One       Date:  2015-04-15       Impact factor: 3.240

3.  In Situ Determination of Bisphenol A in Beverage Using a Molybdenum Selenide/Reduced Graphene Oxide Nanoparticle Composite Modified Glassy Carbon Electrode.

Authors:  Rongguang Shi; Jing Liang; Zongshan Zhao; Yi Liu; Aifeng Liu
Journal:  Sensors (Basel)       Date:  2018-05-22       Impact factor: 3.576

4.  Preparation and characterization of molecularly imprinted solid-phase extraction column coupled with high-performance liquid chromatography for selective determination of melamine.

Authors:  Q Zhou; X C Tan; X J Guo; Y J Huang; H Y Zhai
Journal:  R Soc Open Sci       Date:  2018-09-12       Impact factor: 2.963

5.  Evaluation of estrogenic chemicals in capsule and French press coffee using ultra-performance liquid chromatography with tandem mass spectrometry.

Authors:  Junichi R Sakaki; Melissa M Melough; Anthony A Provatas; Christopher Perkins; Ock K Chun
Journal:  Toxicol Rep       Date:  2020-08-21

6.  Surface blocking of azolla modified copper electrode for trace determination of phthalic acid esters as the molecular barricades by differential pulse voltammetry: response surface modelling optimized biosensor.

Authors:  Maryam Darvishi; Shahab Shariati; Fariba Safa; Akbar Islamnezhad
Journal:  RSC Adv       Date:  2021-10-05       Impact factor: 4.036

  6 in total