Literature DB >> 23726340

Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models.

Mi-Ju Bae1, Ji-Young Kim, Jong-Tae Park, Jung-Yul Cha, Hee-Jin Kim, Hyung-Seog Yu, Chung-Ju Hwang.   

Abstract

INTRODUCTION: Several methods are available to enhance the precision of miniscrew placement. The use of surgical guides based on cone-beam computed tomography is indicated especially in patients with risky or difficult anatomic situations. The purpose of this study was to evaluate the accuracy of miniscrew placement by using surgical guides developed with computer-aided design and manufacturing techniques.
METHODS: Miniscrews were placed in cadaver maxillae using stereolithographic computer-aided design and manufacturing techniques with assistance from surgical guides (surgical guide group, n = 25) or periapical x-rays (control group, n = 20). Insertion sites were selected using a 3-dimensional surgical planning program by fusing maxillary digital model images and cone-beam computed tomography images. Deviations between actual and planned placements were measured as 3-dimensional angular deviations and distance (coronal and apical) deviations.
RESULTS: In the surgical guide group, the angular deviation was a median of 3.14° (range, 1.02°-10.9°), and the mesiodistal deviations in the coronal and apical areas were medians of 0.29 mm (range, 0.03-0.73 mm) and 0.21 mm (range, 0.03-0.97 mm), respectively. The deviations differed significantly between operators in the control group, but not in the surgical guide group. In the surgical guide group, there was no root damage from miniscrew placement, and 84% of the miniscrews were placed without contacting adjacent anatomic structures. In the control group, 50% of the miniscrews were placed between the roots (P <0.05).
CONCLUSIONS: Surgical guide accuracy was improved when digital model imaging was used. Miniscrews were placed more accurately when using surgical guides than when using a direct method.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23726340     DOI: 10.1016/j.ajodo.2013.02.018

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Accuracy of stereolithographically printed digital models compared to plaster models.

Authors:  Leonardo Tavares Camardella; Oswaldo V Vilella; Marleen M van Hezel; Karel H Breuning
Journal:  J Orofac Orthop       Date:  2017-03-30       Impact factor: 1.938

2.  Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study.

Authors:  Li Su; Hui Song; Xiaofeng Huang
Journal:  BMC Oral Health       Date:  2022-06-24       Impact factor: 3.747

3.  Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT.

Authors:  Georgios Vasoglou; Ioanna Stefanidaki; Konstantinos Apostolopoulos; Evmorfia Fotakidou; Michail Vasoglou
Journal:  Dent J (Basel)       Date:  2022-06-08

4.  Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement.

Authors:  Silvia Izabella Pop; Mircea Dudescu; Sorin Gheorghe Mihali; Mariana Păcurar; Dana Cristina Bratu
Journal:  Polymers (Basel)       Date:  2022-05-21       Impact factor: 4.967

5.  Dental extrusion with orthodontic miniscrew anchorage: a case report describing a modified method.

Authors:  Ricardo Fidos Horliana; Anna Carolina Ratto Tempestini Horliana; Alexandre do Vale Wuo; Flávio Eduardo Guillin Perez; Jorge Abrão
Journal:  Case Rep Dent       Date:  2015-02-02

6.  Suitability of virtual plaster models superimposed with the lateral cephalogram for guided paramedian orthodontic mini-implant placement with regard to the bone support.

Authors:  Stephan Christian Möhlhenrich; Maximilian Brandt; Kristian Kniha; Anna Bock; Andreas Prescher; Frank Hölzle; Ali Modabber; Golamreza Danesh
Journal:  J Orofac Orthop       Date:  2020-07-06       Impact factor: 1.938

7.  Clinical effectiveness of orthodontic miniscrew implantation guided by a novel cone beam CT image-based computer aided design and computer aided manufacturing (CAD-CAM) template.

Authors:  Lingling Qiu; Hui Xu; Pingping Feng; Xiaoyan Sha; Hongwei Zhang
Journal:  Ann Transl Med       Date:  2021-06
  7 in total